22
Battery
Shore Power
Load
ATS ON
AC IN
AC OUT
5A
B2-05=5A
3A
Solar
Charger
Solar Panel
or
3A
AC Charger
OFF
3.
Power Assist Mode
And now the other load adds and the current increases to 11A. This is where Power
Assist function is needed!
(ATS ON + AC CHARGER OFF + INVERTER ON + Power Assist Mode ON)
As soon as the load reduces to less than 5A, power assist function stops.
Battery
Shore Power
Load
ATS ON
AC IN
AC OUT
5A
B2-05=5A
11A
Solar
Charger
Solar Panel
or
5A
6A
90A