51
Menu
Group
Function
Constant
LCD Display
Range
Unit
Factory
Setting
Remark
Page
C1-05
Power Assist Select
0~1
1
1
0: Disable
1: Enable
71
Programm-
ing
C
Inverter
C1
Inverter
C1-06
Power Assist Level
1.0~3.5
0.1
2.0
72
D1-02
Charge Curve
1~3
1
3
1: Fixed
2: Adaptive
3: Asafe
73
D1-03
Absorption Voltage
NOTE 3
0.01V
NOTE 3
74
D1-04
Rep-Absorption Time
1~72
0.25hou
r
4
4x0.25=1 hour
74
D1-05
Rep-Abs Interval
1~180
0.25day
28
28x0.25=7day
74
D1-06
Max. Absorption Time
1~8
1hour
4hour
74
D1-07
Float Voltage
NOTE 3
0.01V
NOTE 3
74
D1-08
Charge Current
NOTE 3
1A
NOTE 3
74
D1-09
Stop After 10Hr Bulk
0~1
1
1
0:Disable
1:Enable
74
D
Charger
D1
Charger
D1-10
Equalize Mode Select
0~1
1
1
0:Disable
1:Enable
75
E1-01
LOAD Higher than ? A
NOTE 3
0.01A
NOTE 3
76
E1-02
LOAD Higher for ? sec
0~255
1sec
0sec
76
E1-03
Udc Lower than ? V
NOTE 3
0.01V
NOTE 3
76
E1-04
Udc Lower for ? sec
0~255
1sec
0sec
76
E1-05
Udc Higher than ? V
NOTE 3
0.01V
NOTE 3
76
E1-06
Udc Higher for ? sec
0~255
1sec
0sec
76
E1-07
Not Charge for ? sec
0~255
1sec
0sec
76
E1-08
Fan On for ? sec
0~255
1sec
0sec
76
E1-09
When bulk Protection
0~1
1
0
0:Disable
1:Enable
77
E1-10
System Fault Occurs
0~1
1
0
0:Disable
1:Enable
77
E1-11
Temp. Alarm Sel
0~1
1
0
0:Alarm
1:Pre-alarm
77
E
Aux-Relay
E1
Set Aux-
Relay 1
ON
E1-12
Temp. Alarm for ?sec
0~255
1sec
0sec
77
Summary of Contents for PM-1500SI-12X
Page 17: ...17 Battery Shore Power Max 5A Load ATS ON AC IN AC OUT 5A 2A 30A 5A B2 05 5A 3A ...
Page 31: ...31 3 4 Battery Connection 3 4 1 Star Connection Schematic ...
Page 32: ...32 3 4 2 Rail Connection Schematic ...
Page 37: ...36 4 1 The following is the structure of user constants ...
Page 38: ...37 ...
Page 39: ...38 ...
Page 40: ...39 ...