28
Note:
1.
When pressing RUN/STOP key, the holding time to remain on the key has to be at least 2
seconds (initial setting) to activate the RUN or STOP function in order to avoid any
accidental pressing on the RUN/STOP key. The second time can be adjusted in RUN/STOP
KeyHoldTime (O2-07).
2.
When changing any of four modes to another mode, Stackable Inverter has to STOP and then
press the desired mode key. When pressing MODE 1 or MODE 2 or MODE 3 or MODE 4
key, the holding time has to remain on the key has to be at least 5 seconds (initial setting) to
activate the mode change in order to avoid any accidental pressing on the mode keys. The
second time can be adjusted in MODE Key Hold Time (O2-06).
3.
The beep sound of key pressing can be selected to be enabled or disabled in Key Pressed
Beep Sel (O2-01)
4.
When all the keys are not pressed at all for a certain time (O1-02), it goes to idle mode. Once
any key is pressed, the display will return to the LCD monitor selection value set in constant
O1-01.
5.
When all the keys are not pressed at all for a certain time (O2-09), all the LCD Display and
LED Indicators are not active but RUN/STOP indicator remains active. The display idle
function can save the display power.
6.
Press
△
key to increase the setting value and
▽
key to decrease the setting value. Press
△
and
▽
keys at the same time to enable the cursor to move to the left digit from the current
digit. For example, if the current digit stays in decimal, press
△
and
▽
at the same time
for the digit to move to centesimal.
Summary of Contents for PM-1500SI-12X
Page 17: ...17 Battery Shore Power Max 5A Load ATS ON AC IN AC OUT 5A 2A 30A 5A B2 05 5A 3A ...
Page 31: ...31 3 4 Battery Connection 3 4 1 Star Connection Schematic ...
Page 32: ...32 3 4 2 Rail Connection Schematic ...
Page 37: ...36 4 1 The following is the structure of user constants ...
Page 38: ...37 ...
Page 39: ...38 ...
Page 40: ...39 ...