93
The battery is too small.
Reduce the charging current
or use a battery with a higher
capacity.
A defective battery.
Replace the battery.
The battery is overcharged.
The battery is too hot.
Connect a Battery
Temperature Sensor (BTS-3)
Battery over temperature
(
>
50
℃
)
1. Allow battery to cool
down.
2. Place battery in a cool
environment.
3. Check for shorted cells.
Battery charge current drop
to 0 A when the absorption
voltage is reached.
Battery Temperature Sensor
(BTS-3) is faulty
1.
Unplug Battery
Temperature Sensor
(BTS-3) from
“Stackable Inverter” and
power
off the “Stackable
Inverter”
then wait 5 seconds and
power on again.
2.
If the “Stackable
Inverter” AC
CHARGE normally, the
BTS-3 is faulty and
needs to be replaced.