Once the device is connected, set the following parameters as
follows:
Parameter
Description
Setting
DRV-03
Start / Stop control
mode
Int.485 RS485 communication.
DRV-04
Frequency control
mode
Int.485 RS485 communication.
DRV-91
Optional Start / Stop
control mode
Keypad
Fx/Rx-1
Fx/Rx-2
Selection of Start / Stop control mode when the
inverter control will be given by communication net.
DRV-92
Optional frequency
control mode
Keypad-1
Keypad-2
V1
V1S
I
V1 + I
Pulse
Selection of the frequency control mode when the
inverter control will be given by communication net.
I/O-20...27
Multi-function digital
input. M1...M8
terminal
Main-drive It allows that the inverter will be controlled through
communication net without additional changes.
I/O-90
Slave number in
communication net
1 – 250 Use different numbers in case of more than 1 inverter
are installed.
I/O-91
Transmission speed
in communication net 9600bps (Default setting).