Administrator Guide - SoundPoint
®
IP / SoundStation
®
IP
Optimization
Copyright © 2005 Polycom, Inc.
119
4.6.1.18 Event Logging <logging/>
The event logging system supports the following classes of events:
Each event in the log contains the following fields separated by the | character:
• time or time/date stamp
• 1-5 character component identifier (such as “so”)
• event class
• cumulative log events missed due to excessive CPU load
• free form text - the event description
ind.gi.x.y.physW
IP 300: n/a
IP 500: 1-160
IP 600: 1-320
IP 4000: 1-248
For GraphicIcon type indicators, this is the width of the
indicator measured in pixels.
ind.gi.x.y.physH
IP 300: n/a
IP 500: 1-80
IP 600: 1-160
IP 4000: 1-68
For GraphicIcon type indicators, this is the height of the
indicator measured in pixels.
Warning!
Logging parameter changes can impair system operation. Do not change any logging parameters
without prior consultation with Polycom.
Level
Interpretation
0
Debug only
1
High detail event class
2
Moderate detail event class
3
Low detail event class
4
Minor error - graceful recovery
5
Major error - will eventually incapacitate the system
6
Fatal error
Attribute
Permitted
Values
Interpretation