Administrator Guide - SoundPoint IP / SoundStation
®
IP
Optimization
120
Copyright © 2005 Polycom, Inc.
Three formats are available for the event timestamp:
4.6.1.18.1 Basic Logging <level/><change/> and <render/>
Type
Example
0 - seconds.milliseconds
011511.006
-- 1 hour, 15 minutes, 11.006 seconds
since booting.
1 - absolute time with minute resolution
0210281716
-- 2002 October 28, 17:16
2 - absolute time with seconds resolution
1028171642
-- October 28, 17:16:42
Attribute
Permitted
Values
Default
Interpretation
log.level.change.xxx
0-5
4
Control the logging detail level
for individual components.
These are the input filters into
the internal memory-based log
system.
log.render.level
0-6
1
Specifies the lowest class of
event that will be rendered to
the log files. This is the output
filter from the internal mem-
ory-based log system.
log.render.type
0-2
2
See above table for timestamp
type.
log.render.realtime
0, 1
1
Set to 1. Do not change.
log.render.stdout
0, 1
1
Set to 1. Do not change.
log.render.file
0, 1
1
Set to 1. Do not change.
Example:
011511.006|so |2|00|soCoreAudioTermChg: chassis -> idle
time stamp
ID
event class
missed events