Administrator Guide - SoundPoint
®
IP / SoundStation
®
IP
Optimization
Copyright © 2005 Polycom, Inc.
117
301 phones, IP_500 parameters affect SoundPoint
®
IP 500 and 501 phones and
IP_600 parameters affect SoundPoint
®
IP 600 and 601 phones.
4.6.1.17.2 Patterns <Patterns/>
This section defines patterns for the LED indicators. In the following table,
x
is the
pattern number,
y
is the step in the pattern.
4.6.1.17.3 Classes <Classes/>
This section defines the available classes for the LED and graphical icon indicator
types. In the following table,
x
is the class number,
y
is the identifier of the state num-
ber for that class.
Attribute
Permitted Values
Interpretation
ind.anim.x.y.frame.z.bitmap
A bitmap name
defined previously.
Bitmap to use.
Note that it must be defined already, see
4.6.1.16.1 Platform <IP_300/>, <IP_500/
>, <IP_600/> and <IP_4000/> on
page 116.
ind.anim.x.y.frame.z.duration
positive integer
Duration in milliseconds for this step.
0=infinite.
Attribute
Permitted
Values
Interpretation
ind.pattern.x.step.y.state
On or Off
Turn LED on or off for this step.
ind.pattern.x.step.y.duration
positive integer
Duration in milliseconds for this step. 0=infinite
ind.pattern.x.step.y.colour
Red or Green
(default is Red
if not specified)
For bi-color LEDs, specify color.
Attribute
Permitted
Values
Interpretation
ind.class.x.state.y.index
positive integer
For LED type indicators, index refers to the pattern
index, such as index x in the <Patterns/> tag above.
For GraphicIcon type indicators, index refers to the
animation index, such as index y in the <Anima-
tions/> tag above.