PDC 2000/3000 Repair Manual
Testing & Adjustment
4. Once the LabView VI test program is loaded, the Big Hose clock front panel appears.
5. Click on the white run arrow. Arrow should change to black.
Note:
Observe the camera window when you click on the run arrow. It instantly
indicates that the camera is connected upon clicking on the run arrow.
6. Unplug the camera power connector and then reconnect it. The camera window
will indicate that the internal hard drive is now set for 60MB.
Note: Never power down the camera with the camera On/Off button.
7. Run the Serial Number VI test to rewrite the camera’s internal serial number to match the
serial number on the camera’s label.