31
PDC 2000/3000 Repair Manual
Testing&Adjustment
15. Place the camera onto the Diorama bench test fixture (camera nest).
16. Flip down the checker/resolution target. Camera should be aimed at Macbeth Color
Checker Chart (Figure 3-4).
17. Click on the Start button to automatically start the focus part of this calibration
procedure.
Note: Follow all instructions that appear on the screen while the focus part of this
calibration procedure runs. Click on the appropriate responses that appear in
the dialog boxes.
18. Upon completion of the first part of the focus calibration procedure, a prompt appears
indicating that the camera be setup for the horizontal part of the focus calibration
procedure (Figure 3-5).
19. Flip up the checker/resolution target (Figure 3-5).
20. Slide the horizontal target over the checker/resolution target. Camera should be aimed
at horizontal target (Figure 3-5).
21. Click on the Start button to automatically start the horizontal part of the focus calibration
procedure.
Note: Follow all instructions that appear on the screen while the horizontal part of the
focus calibration procedure runs. Click on the appropriate responses that appear
in the dialog boxes.