44
PDC 2000/3000 Repair Manual
Testing & Adjustment
4. Once the LabView VI test program is loaded, the Serial Number front panel appears.
5. Select camera type. Scroll through the camera type box and then click on the applicable
camera type.
6. Click on the Configuration Box and then enter the camera configuation code.
6. Click on Customize Serial Number window.
7. Click on the white run arrow. Arrow should change to black. The Password Checker VI
window appears.
Note:
If Lock symbol is displayed, enter password exactly as shown (No space, Initial
Cap, rest lower case):
Unlock
Configuration
Code
Camera Serial Number:
079617 - 34 GQ - K40
Camera Type
Box