PDC 2000/3000 Repair Manual
Testing & Adjustment
4. Once the LabView VI test program is loaded, the Fast Flatness Test front panel appears.
5. Set Start Step to 37.
6. Set End Step to 47.
7. Click on the white run arrow. Arrow should change to black. This action starts the
selected LabView VI test program.
8. Upon completion of the Fast Flastness Test procedure, the Fast Flatness Test front
panel indicates the Peak Tolerances/Location.
Notes: •
If the Top/Bottom and Left/Center/Right
buttons are
green
, camera focus
OK. Peak Tolerances/Location high point should be at 42+\- 4.
•
If the Top/Bottom and Left/Center/Right
buttons are
red
, camera focus
incorrect. Re-collimate camera.