19
PDC 2000/3000 Repair Manual
Testing&Adjustment
Testing and Adjustments
Current Profile Test
Required Test Equipment and Tools
• Macintosh Centris 650 Computer or Equivalent
• 1-ohm resistor box
• 0 - 10 Vdc Power Supply
• Camera Test Fixture (Nest)
Equipment Setup (Figure 3-1)
1. Place the camera onto a workbench.
2. Connect the external power supply output cable to the 6 Vdc input on the 1-ohm resistor
box.
3. Connect the 1-ohm resistor box 6 Vdc output cable to the camera power jack.
4. Connect the computer ribbon cable to the 1-ohm resistor box.
5. Turn on the test equipment as follows:
• Macintosh Centris 650 computer On/Off (0/1) switch to On (1).
• 0 - 10 Vdc external power supply On/Off switch to On. Adjust power supply output to
6 Vdc.