XSYNC Connector (Figure 2-11)
Removal
1. Remove the rear panel and XSYNC assembly.
2. Using a small flat scredriver, remove the screw securing the XSYNC cable to the XSYNC
assembly.
Note: XSYNC assembly consists of:
•
XSYNC assembly (connector)
•
XSYNC cable and screw
•
Nylon shoulder washer
3. Using the XSYNC nut driver, remove the nut and lug cable asssembly that secures the XSYNC
assembly to the rear panel.
Note: Nut and lug assembly consists of:
•
nut
•
Inner shoulder washer
•
XSYNC lug cable
4. Lift off the XSYNC assembly and nut and lug cable assembly from the rear panel.