11-222
Example:
Set the transmission interval of Information OAMPDU for ethernet 1/4 to be 2s.
Switch(Config-If-Ethernet1/4)# ethernet-oam period 2
11.22 ethernet-oam remote-failure
Command:
ethernet-oam remote-failure
no ethernet-oam remote-failure
Function:
Enable remote failure indication of OAM, no command disables the function.
Parameters:
None.
Command Mode:
Port mode
Default:
Enable.
Usage Guide:
With remote failure indication is enabled, if critical-event or link fault event is occurred locally, it will notify the peer by
sending Information OAMPDU, log the fault information and send SNMP trap warning. When the remote failure
indication is disabled, although local critical-event or link fault event is not monitored, failure indication information
from the peer is still normally received and processed.
Example:
Enable remote failure indication of ethernet 1/4.
Switch(Config-If-Ethernet1/4)#ethernet-oam remote-failure