47
<DRC1285>
En
English
Others
Message display
Host must return
all hyper’s disc
scsiID=7 TermOFF
dev-ID=
E88, E89,E99, etc.
¶
Memory Failure
¶
Error
Possible cause
There are some discs that from
the hyper magazine remaining in
drives.
¶
SCSI cable has not been
connected properly.
¶
SCSI ID or termination
settings have not been
correctly specified.
¶
The total length of the SCSI
cables is too long.
¶
Operator has forgotten to
reboot the host computer.
¶
The power cable for the drive
in question has not been
connected.
¶
Drives have been inserted in
rear bays #9 through #16
without additional power
supply unit.
¶
The disc has been inserted
upside down.
¶
The disc is soiled or
scratched.
A mechanical error has occurred
which has made the changer
unable to continue in operation.
The changer SCSI termination
switch is set to OFF or the SCSI
cable is not properly connected.
Magazine's memory data is not
being read correctly.
Description of problem
Hyper magazine cannot be ejected
in Hyper submode.
There exists a drive or drives which
fail to be recognized by the host
computer even though they have
been recognized in Config submode.
There exists a drive which fails to be
recognized by the host computer,
and the SCSI ID of the drive is set to
‘7’ when checked in Config
submode.
Unable to properly read a disc which
has been inserted in a drive.
An error code is displayed on the
LCD message window and the
backlight flashes and the buzzer is
sounded.
The LCD message window does not
come on when the power is turned
on.
Pressing the operation keys has no
effect.
Buzzer sounds when magazine is
loaded.
Recommended action
Return to user mode, issue REZERO
command from the host computer
requesting that all discs be returned,
and try to perform the operation again
after all discs have been returned.
¶
Make sure that the SCSI cables have
been connected properly.
¶
Check to see if there is any device on
the same bus with the same SCSI ID
and to see that the SCSI chain has
been properly terminated.
¶
Re-configure the SCSI chain so that
the total length of all the cables does
not exceed the maximum allowable
length.
¶
Reboot the host computer.
¶
Open the rear access door and check
to see if the power cable has been
properly connected.
¶
The power supplied by the power
supply included as standard
equipment is sufficient only for
operating drives in bays #1 through
#8. Reinstall the drive in one of these
bays or install the additional power
supply unit.
¶
Check to see if the disc has been
inserted upside down.
¶
Check to see if the disc is soiled or
scratched, and wipe away any soil or
replace the disc.
In system administrator mode, open the
access door and take whatever action is
required in order to eliminate the error
condition.
¶
When installing is not finished, turn
the SCSI termination switch to ON
and turn the power OFF and ON.
¶
If the SCSI cable is not properly
connected, turn off the power. And
after connection the cable properly,
turn on the power again.
¶
Remove and reinsert magazine.
¶
If the magazine data still can't be read
properly, perform a "PROBE" of the
magazine, ten open and close the
door.
Summary of Contents for DRM-300
Page 2: ...2 DRC1285 En ...