44
<DRC1285>
En
Operation
4. Make sure the wiring monitor indicator (orange). It is
located on the back of the drive and ought to be
flashing at half-second intervals if the drive has been
selected in Step 3. Then disconnect the cables to the
drive.
Order in which cables are to be disconnected:
1. SCSI interface cable
2. Changer interface cable
3. Power cable
5. Remove the drive.
If it is difficult to work, the SCSI interface cables of other
drives should be disconnected before continuing.
6. Check the SCSI ID and termination switch settings of
the drive which has just been removed, and set the
SCSI ID and termination switch settings of the drive
which is to be inserted in its place to the same settings.
¶
Since the DVD-R7783 is not provided with a terminator,
no termination setting is provided for that unit.
7. Insert the new drive and connect the power cable.
¶
When the power cable has been connected, the wiring
monitor indicator on the rear of the drive (orange) will
light up.
¶
When terminator switch is set to ON, the termination
indicator (green) also lights (does not apply to DVD-
R7783).
8. Connect the changer interface cable.
¶
When the changer interface cable has been connected,
the wiring monitor indicator will begin flashing at half-
second intervals.
9. Compare the SCSI ID and termination settings of the
newly installed drive against those of the removed
drive.
¶
If the SCSI ID of the new drive is the same as that of
the drive which has just been removed, the buzzer will
sound once.
¶
If the SCSI ID of the new drive is not the same as that
of the drive which has just been removed, the buzzer
will sound three times.
10. Connect the SCSI interface cable.
If you have disconnected the SCSI interface cables of any
other drives in Step 5, be sure to remember to reconnect
those cables.
11. Check the drive device ID displayed on the LCD
message window.
Press the ENT key
≠
NOTES:
¶
If the SCSI ID and termination switch settings displayed
differ from those which set on the back of the drive, or if a
drive’s device ID fails to be displayed, it is likely that the
corresponding cables were improperly connected. If this
happens, follow the steps outlined below to properly
reconnect all the cables.
Order in which cables are to be disconnected:
1. SCSI interface cable
2. Changer interface cable
3. Power cable
Order in which cables are to be reconnected:
1. Power cable
2. Changer interface cable
3. SCSI interface cable
¶
If the device ID of a drive cannot be read, then it will be
impossible for the host computer to perform automatic
configuration.
Power cable
Wiring monitor indicator
Termination indicator
(Busy indicator on DVD-R7783)
Changer interface cable
Wiring monitor indicator