Page 47
For HELP, call 800.304.9684
MESSAGE MEANING
ACTION
REQUIRED
HFL
HL
A substantial difference
between sensors was
detected (possible flow
problem).
Check water level in hot tub
and add water if necessary. Be
sure that slide-valves are open.
Make sure the pump is primed
and has power. If the problem
persists, contact service.
LF
Low Flow
– persistent
problem. Displays after
the fifth occurrence of
the "HL" message within
24 hours. Heater shuts
down but other hot tub
functions run normally.
Heating ability of the hot tub will
not reset automatically; press
any button to reset.
dr
Inadequate water, poor
flow, or air bubbles
detected in the heater.
Hot tub is shut down for
15 minutes.
Check the water level and add
water if necessary. Be sure that
slide-valves are open. Make
sure the pump is primed and
has power. Press any button to
reset (automatically reset within
15 minutes). If the problem
persists, contact service.
drY
dy
Inadequate water
detected in heater.
Displays on third
occurrence of "dr"
message. Hot tub is shut
down.
Check water level in hot tub.
Add water if necessary. Be sure
that slide-valves are open.
Make sure the pump is primed
and has power. Press any
button to reset.
Pr
When your hot tub is first
activated, it goes into
Priming mode.
The Priming mode runs for up
to four minutes and then the hot
tub begins to heat and maintain
the water temperature in
Standard mode.
- - F
Temperature unknown
After the pump has been
running for two minutes, the
temperature will be displayed.
- - C
Temperature unknown
After the pump runs for two
minutes, the temperature
displays
NOTE: SEE ALSO PAGE 39 FOR PN MODELS ERROR CODES.
Summary of Contents for LUXURY DX 5000
Page 13: ...Page 11 For HELP call 800 304 9684...
Page 18: ...Page 16 For HELP call 800 304 9684...
Page 36: ...Page 34 For HELP call 800 304 9684...
Page 38: ...Page 36 For HELP call 800 304 9684 Programming Steps for PN Models...
Page 70: ...6101 45th St N St Petersburg FL 33714 800 304 9684 www PinnacleSpas com...