Commissioning
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 87
Installation of the adjustment template with bracket (see Order reference for accessories):
}
Fasten the template to the bracket using half length taper-grooved dowel pins and cylin-
der head bolts (see illustration).
10
45
65
Ø 3
+0,1
Ø 3,4
Ø 3,4
Ø 3
+0,1
1
3
2
Fig.: Adjustment template to attach to bracket
}
1: Ø 3 mm DIN 1472 half length taper-grooved dowel pin
}
2: M3 x 10 cylinder head bolts
}
3: Ø 3 mm DIN 1472 half length taper-grooved dowel pin
}
Attach the bracket to the upper tool clamp.
1
Fig.: Adjustment template with bracket