Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 56
}
Upward movement, advance measuring field is cleared
Protected field: Free or interrupted
Dynamic muting: Inactive
Position = Frozen value
Signal/action
Status
Press
Foot switch
1 or 0
v < 0
System-Init
0
OSSD
1 or 0
Mute
0 -> 1
Muting OSSD
Inactive
Monitoring of braking ramp
Inactive
Monitoring of pinch point
Inactive
The foot switch may only be released during a safe upward movement.
}
Press is at top dead centre
Protected field: Free
Dynamic muting: Inactive
Position = Protected field height (including r advance measuring field)
Position =
<Configured overrun>
+ 6 mm + 2 mm
Signal/action
Status
Press
Foot switch
0
v = 0
TDC
System-Init
1
OSSD
1
Mute
1
Muting OSSD
Inactive
Monitoring of braking ramp
Inactive
Monitoring of pinch point
Inactive