Installation
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 71
5
Installation
5.1
General requirements
Please note during installation:
}
The PSENvip may only be installed by qualified personnel.
}
The environmental data for the PSENvip must be taken into account (see Technical de-
tails).
}
The transmitter and receiver should be installed with the respective front lenses aligned in
parallel to each other.
}
The distance between transmitter and receiver must be maintained (see
Technical
Details [
113]
).
WARNING!
A restricted field of vision or inadequate mounting will restrict the pro-
tected field!
A restricted protected field may lead to serious injury and death.
Ensure that the field of vision of the front lenses on the transmitter and re-
ceiver is not restricted. Do not attach any other optical elements such as
glass/plastic surfaces, films or lenses.
– Check the mounting of the transmitter and receiver on a regular
basis.
– Check that the mounting of the transmitter and receiver is not acci-
dentally working its way loose as a result of vibration from the press
brake.