Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 45
4.8.2.2
Acknowledgement after protected field meets the workpiece
The press stroke is stopped when the protected field meets the workpiece. The reduced
protected field starts after the downward movement is stopped with the acknowledgement
(e.g. acknowledgement button). The following states are available:
}
Press is at top dead centre
Protected field: Free
Signal/action
Status
Press
Foot switch
0
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0
System-Init
1
OSSD
1
Creep speed
0
}
Downward movement (rapid traverse)
Full protected field active
Protected field: Free
Signal/action
Status
Press
Foot switch
1
v = 0
v > 10 mm/s
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0
System-Init
0
OSSD
1
Creep speed
0
}
Downward movement is stopped, full protected field meets the workpiece
Protected field: Interrupted