Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 62
4.9.2.2
Acknowledgement after protected field meets the workpiece
The press stroke is stopped when the protected field meets the workpiece. The reduced
protected field starts after the downward movement is stopped with the acknowledgement
(e.g. acknowledgement button). The following states are available:
}
Press is at top dead centre
Protected field: Free
Dynamic muting: Inactive
Position = Protected field height (including r advance measuring field)
Position =
<Configured overrun>
+ 6 mm + 2 mm
Signal/action
Status
Press
Foot switch
0
v = 0
TDC
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0
System-Init
1
OSSD
1
Mute
1
Muting OSSD
Inactive
Monitoring of braking ramp
Inactive
Monitoring of pinch point
Inactive
}
Downward movement (rapid traverse)
Full protected field active
Protected field: Free
Dynamic muting: Inactive
Position = Protected field height (including r advance measuring field)
Position =
<Configured overrun>
+ 6 mm + 2 mm
Signal/action
Status
Press
Foot switch
1
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0
System-Init
0
OSSD
1
Mute
1
Muting OSSD
Inactive
Monitoring of braking ramp
Inactive
Monitoring of pinch point
Inactive