Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 63
}
Downward movement is stopped, full protected field meets workpiece
Protected field: Interrupted
Dynamic muting: Inactive
Position = Protected field height (including r advance measuring field)
Position =
<Configured overrun>
+ 6 mm + 2 mm
Signal/action
Status
Press
Foot switch
1
v = 0
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0
System-Init
0
OSSD
1 -> 0
Mute
1
Muting OSSD
Inactive
Monitoring of braking ramp
Inactive
Monitoring of pinch point
Inactive
}
Downward movement is continued with reduced protected field, start via acknow-
ledgement
Protected field: Free
Dynamic muting: Inactive
Position = Protected field height (including r advance measuring field)
Position =
<Configured overrun>
+ 6 mm + 2 mm
Signal/action
Status
Press
Foot switch
1
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0 -> 1
System-Init
0
OSSD
1
Mute
1
Muting OSSD
Inactive
Monitoring of braking ramp
Inactive
Monitoring of pinch point
Inactive
}
Downward movement, advance measuring field touches workpiece at the pinch
point (KP)
Protected field: Free
Dynamic muting:
Start