Change, maintenance
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 109
10.1
Regular checks and maintenance
The following checks must be carried out at regular intervals:
Interval
Function test with:
Test rod
Test piece (10, 15
mm)
Test piece (35 mm)
10 x during initial
commissioning
x (with upper tool
over whole length of
machine)
x (with upper tool
over whole length of
machine)
Each time it is
switched on
x
x
After 3 months
x
x
1 x per year
x (with upper tool
over whole length of
machine)
x (with upper tool
over whole length of
machine)
x (with upper tool
over whole length of
machine)
After tool change
x
x
x
after Firmware up-
date
x
x
x
Carry out the test as described under Test the function of the safeguard.
INFORMATION
This inspection may only be carried out by qualified personnel
}
Visual inspection of transmitter and receiver for
:
– Condition of the installation and attachment
– Any damage on the housing and lens
– Damage to the electrical connections
– Contamination on the lens
– Check the messages on the display.
Test interval
– Regular, depending on the pollution of the surrounding area
}
Inspection of safeguards and protection measures on the press brake
Test intervals:
– At least annually (more frequently depending on use)