Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 57
4.9.2
System cycle for box bending press stroke
PSENvip transfers position values to the special module PSSu K F FAU P (see I/O data
type PROTECTION_FIELD_SIZE), which can be used in the user program for feasibility
testing.
Please note:
}
On each press stroke, the "Reduced protected field" protected field mode
must
be star-
ted via an acknowledgement. The acknowledgement can take place either when the
press stroke is started at top dead centre or after the protected field meets the workpiece
(see
Protected field modes [
23]
).
}
In box bending protected field mode, the front segments of the protected field are
blanked.
4.9.2.1
Acknowledgement when starting at top dead centre
The reduced protected field starts with an acknowledgement (e.g. acknowledgement but-
ton), when the downward movement is started at top dead centre (TDC). The following
states are available:
}
Press is at top dead centre
Protected field: Free
Dynamic muting: Inactive
Position = Protected field height (including r advance measuring field)
Position =
<Configured overrun>
+ 6 mm + 2 mm
Signal/action
Status
Press
Foot switch
0
v = 0
TDC
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0
System-Init
1
OSSD
1
Mute
1
Muting OSSD
Inactive
Monitoring of braking ramp
Inactive
Monitoring of pinch point
Inactive
}
Downward movement (rapid traverse)
Protected field: Free
Dynamic muting: Inactive
Position = Protected field height (including r advance measuring field)
Position =
<Configured overrun>
+ 6 mm + 2 mm