Function description
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 58
Signal/action
Status
Press
Foot switch
1
Acknowledgement of "re-
duced protected field" pro-
tected field mode
0 -> 1
System-Init
0
OSSD
1
Mute
1
Muting OSSD
Inactive
Monitoring of braking ramp
Inactive
Monitoring of pinch point
Inactive
}
Downward movement, advance measuring field touches workpiece at the pinch
point (KP)
Protected field: Free
Dynamic muting:
Start
Position = Protected field height (including r advance measuring field)
Position =
<Configured overrun>
+ 6 mm + 2 mm – (2 mm from first muting stage)
Position =
<Configured overrun>
+ 6 mm
Signal/action
Status
Press
Foot switch
1
KP
Acknowledgement of "re-
duced protected field" pro-
tected field mode
1 or 0
System-Init
0
OSSD
1
Mute
1 -> 0
Muting OSSD
Inactive
Monitoring of braking ramp
Start
Monitoring of pinch point
Active
}
Downward movement, gradual reduction of protected field
Protected field: Free
Dynamic muting: Active
Position = Protected field height (including r advance measuring field)
Position =
<Configured overrun>
+ (6 mm + 2 mm) – (2 mm x number of muting stages)
Example for 2nd muting stage: Position =
<Configured overrun>
+ 4 mm