Commissioning
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 97
7.2.2.2
Adjustment in the web interface
Open the
Tool change
page in the web interface. You will see the tool centre point with
guides.
Example of the representation:
[1]
[4]
[3]
[2]
}
1: Tool centre point
}
2: Range bar
}
3: Adjustment line
}
4: Central and rear bending line
The vertical position of the tool centre point must be within the range bar. If the adjustment
line is at the upper or lower end of the range bar, the
symbol will appear and the "Out
of range" message will be displayed.
If the
symbol appears on the display, there is a problem with the lighting of the receiver
by the transmitter:
}
Check that the transmitter and receiver are aligned correctly. The illuminated target area
must completely envelop the receiver. If necessary, realign the transmitter (see
Align
transmitter [
85]
).
}
Remove any potential contamination on the lens of the transmitter or receiver.
The adjustment has been carried out correctly when none of the symbols appear:
}
Accept the adjustment by pressing
Accept
. The button switches to the function
Confirm
.
Confirm the adjustment within 3 seconds by pressing
Confirm
.
You can exit the menu at any time without confirming by
Cancel
or select another option. In
this case, the previous tool data will be retained.