Commissioning
Operating Manual PSENvip R, PSENvip R LR,PSENvip E
1003449-EN-06
| 96
Tool class 3
}
The contour of these tools is not fully detected by the PSENvip.
}
The front (V3) and/or rear (H3) bending lines are within the protected field.
}
These tools are not safeguarded in compliance with the standards.
}
Example:
H
V
Fig.: Example for tool class 3