PG D
RIVES
T
ECHNOLOGY
O
MNI
– D
IAGNOSTICS
SK78813/5
146
3.5
Motor Error
This occurs when the control system detects that a motor has become
disconnected.
3B00 -
M1 Motor Error - Refer to section 2.3 for connection details
3C00 -
M2 Motor Error - Refer to section 2.3 for connection details
•
Check the motors, cables and connections to the control system.
If the trip is still present after the above checks have been made, then the
Power Module may be defective. Refer to Section 5.
3.6
Inhibit Active
This occurs when any of the Inhibit inputs are active and in a latched state.
The actual inhibit that is active is indicated by the last 2 digits in the Trip Code.
The code is in Hex.
1E01 -
For Inhibit 1 - Refer to section 2.3 for connection details
1E09 -
For Inhibit 9 - Refer to section 2.3 for connection details
1E0A -
For Inhibit 10 - Refer to section 2.3 for connection details
•
Cycle the power. This will drop out of Latched Mode that might
clear the trip.
•
Check all wiring and switches connected to the indicated
Inhibits.
If the trip is still present after the above checks have been made, then the ISM
may be defective. Refer to Section 5.
3.7
Joystick Calibration Error
This occurs when the Joystick type SID Calibration process has not been
successful.
•
Enter OBP and attempt calibration.
Summary of Contents for R-NET OMNI
Page 1: ...PG DRIVES TECHNOLOGY R NET OMNI SK78813 5 1 R NET OMNI TECHNICAL MANUAL SK78813 5 ...
Page 16: ...PG DRIVES TECHNOLOGY R NET OMNI SK78813 5 16 ...
Page 17: ...PG DRIVES TECHNOLOGY OMNI STANDARD INSTALLATION SK78813 5 17 CHAPTER 1 INSTALLATION ...
Page 18: ...PG DRIVES TECHNOLOGY OMNI STANDARD INSTALLATION SK78813 5 18 ...
Page 20: ...PG DRIVES TECHNOLOGY OMNI STANDARD INSTALLATION SK78813 5 20 2 Controls and Connections ...
Page 39: ...PG DRIVES TECHNOLOGY OMNI STANDARD OPERATION SK78813 5 39 CHAPTER 2 OPERATION ...
Page 40: ...PG DRIVES TECHNOLOGY OMNI STANDARD OPERATION SK78813 5 40 ...
Page 68: ...PG DRIVES TECHNOLOGY OMNI STANDARD OPERATION SK78813 5 68 ...
Page 69: ...PG DRIVES TECHNOLOGY OMNI STANDARD PROGRAMMING SK78813 5 69 CHAPTER 3 PROGRAMMING STANDARD ...
Page 70: ...PG DRIVES TECHNOLOGY OMNI STANDARD PROGRAMMING SK78813 5 70 ...
Page 76: ...PG DRIVES TECHNOLOGY OMNI STANDARD PROGRAMMING SK78813 5 76 1 3 1 PC Programmer Parameters ...
Page 99: ...PG DRIVES TECHNOLOGY OMNI ADVANCED PROGRAMMING SK78813 5 99 CHAPTER 4 PROGRAMMING ADVANCED ...
Page 100: ...PG DRIVES TECHNOLOGY OMNI ADVANCED PROGRAMMING SK78813 5 100 ...
Page 109: ...PG DRIVES TECHNOLOGY OMNI IR SK78813 5 109 CHAPTER 5 INFA RED CONTROL ...
Page 110: ...PG DRIVES TECHNOLOGY OMNI IR SK78813 5 110 ...
Page 135: ...PG DRIVES TECHNOLOGY OMNI DIAGNOSTICS SK78813 5 135 CHAPTER 5 DIAGNOSTICS ...
Page 136: ...PG DRIVES TECHNOLOGY OMNI DIAGNOSTICS SK78813 5 136 ...
Page 141: ...PG DRIVES TECHNOLOGY OMNI DIAGNOSTICS SK78813 5 141 ...
Page 158: ...PG DRIVES TECHNOLOGY OMNI DIAGNOSTICS SK78813 5 158 ...
Page 159: ...PG DRIVES TECHNOLOGY OMNI SPECIFICATIONS SK78813 5 159 CHAPTER 6 SPECIFICATIONS ...
Page 160: ...PG DRIVES TECHNOLOGY OMNI SPECIFICATIONS SK78813 5 160 ...
Page 167: ...PG DRIVES TECHNOLOGY OMNI WARNING SUMMARY SK78813 5 167 CHAPTER 7 WARNING SUMMARY ...
Page 168: ...PG DRIVES TECHNOLOGY OMNI WARNING SUMMARY SK78813 5 168 ...