Maintenance
260
Replacement Parts: General
Every day you count on PerkinElmer to provide you with solutions that deliver
reliable performance, control operating costs and maximize operational time. Our
complete portfolio of consumables, parts, supplies, training and service helps you
meet both routine and demanding measurement challenges. We invest heavily in
testing and validating our products to ensure you receive guaranteed compatibility
and performance - on-time, every time, for every instrument in your laboratory.
The following replacement parts are required for general system maintenance. For
other replacement parts, refer to the appropriate sections earlier in this chapter.
Table 5-10.
Filters
Part No.
Description
N0776075
Reservoir Water Filter/Strainer
N0777095
Polyscience Chiller Air Filter
09995098
Air Filter for Spectrometer
N0775325
Air Dry Filter Assembly with R250 Regulator
N9306067
Replacement Filter Element (for Air Dry Filter Assembly)
Table 5-11.
Gas and Water Supply Connections
Part No.
Description
09920125
Space Collar for 1/4-in. Swagelok Fittings
09995098
Air Filter for Spectrometer
N0690274
Argon Supply Hose
Summary of Contents for AVIO 200
Page 1: ...AVIO 200 SPECTROMETER Hardware Guide ICP OPTICAL EMISSION ...
Page 2: ......
Page 3: ...AvioTM 200 Spectrometer Customer Hardware and Service Guide ...
Page 12: ...Contents 10 ...
Page 30: ...28 ...
Page 31: ...Safety Practices 1 ...
Page 32: ...30 Safety Practices ...
Page 56: ...54 Safety Practices ...
Page 57: ...Preparing Your Laboratory 2 ...
Page 58: ...Preparing Your Laboratory 56 ...
Page 70: ...Preparing Your Laboratory 68 ...
Page 71: ...System Description 3 ...
Page 72: ......
Page 97: ...Installation 4 ...
Page 98: ......
Page 119: ...Installation 117 Figure 4 8 Replacing the torch 1 3 4 6 8 2 9 10 5 7 ...
Page 121: ...Installation 119 1 2 7 9 8 10 3 4 5 6 ...
Page 164: ...Installation 162 ...
Page 165: ...Maintenance 5 ...
Page 166: ......
Page 184: ...Maintenance 182 1 2 7 9 8 10 3 4 5 6 ...
Page 188: ...Maintenance 186 Figure 5 8 Replacing the Torch 1 3 4 6 8 2 9 10 5 7 ...
Page 272: ...Maintenance 270 ...
Page 273: ...Troubleshooting 6 ...
Page 274: ......
Page 293: ...Troubleshooting 291 Figure 6 1 Normal Plasma Conditions at 0 torch position ...
Page 294: ...Troubleshooting 292 Figure 6 2 Normal Plasma at 3mm position ...
Page 297: ...Troubleshooting 295 Figure 6 5 Injector too far forward ...
Page 298: ...Troubleshooting 296 Figure 6 6 No Aux Gas Torch may be glowing ...
Page 299: ...Troubleshooting 297 Figure 6 7 Air Leak or Spray Chamber Temperature too high ...
Page 300: ...Troubleshooting 298 Figure 6 8 Thin Plasma due to leak in Plasma Gas Line ...
Page 308: ......