![Pentair EASYTOUCH PL4 User Manual Download Page 55](http://html1.mh-extra.com/html/pentair/easytouch-pl4/easytouch-pl4_user-manual_1524370055.webp)
EASYTOUCH
®
PL4/PSL4 Control Systems User’s Guide
47
Settings Menu: 2-Speed Pump
Equipment circuits selected in this menu will automatically switch a two-speed filter pump to high speed when
these circuits are on. If a two-speed pump is assigned to solar, a cleaner or a pump, when activated the pump
will automatically run for five minutes in high speed then switch to low speed. For example, when on, the
filter pump will switch to high speed whenever the JETS or CLEANER is on. There must be a two-speed relay
installed in the EasyTouch PL4/PSL4 Control System Power Center in order for the “2-Speed Pump” menu
settings to function.
2-Speed Pump
To configure a two-speed pump to a circuit:
MENU
s
SETTINGS
s
2-SPEED PUMP
w
2-SPEED PUMP
Settings Menu: Solar
Use the solar settings to setup solar or configure solar as a heat pump:
Setting Up Solar Control
: Ensure
that the solar temperature sensor is installed.
About Installing Solar Heating:
First, install the solar sensor at the collectors and connect to the EasyTouch
PL4/PSL4 Control System Power Center. If HEAT PUMP is selected and is being used in place of a solar
heating system, install Solar sensor near the EasyTouch PL4/PSL4 Control System Power Center. Connect
the wires to the SOLAR screw terminals according to the wiring diagram on page 64. Plug the solar valve
actuator cable into three-pin socket marked VLV A on the EasyTouch PL4/PSL4 Control System main circuit
board. If a solar booster pump is being installed, connect the pump to a power relay and plug a low voltage
cable from relay into the two-pin socket marked SOLAR on the EasyTouch PL4/PSL4 Control System main
circuit board.
To access the Solar menu:
MENU
s
SETTING
w
SOLAR
w
SOLAR
Up/Down buttons:
Select a circuit that will switch the filter pump to high speed. You can set up to four circuits to
use a two-speed pump (
1
/4,
2
/4,
3
/4,
4
/4).
Right button:
Move to assign a circuit setting.
Up/Down buttons:
Select the circuit to assign to a two-speed pump. The generic circuits names are:
NONE, SPA,
POOL, AUX 1-3, FEATURE 1-2, SOLAR, HEATER, POOL HEATER, SPA HEATER and FREEZE.
Selecting
NONE does not assign a circuit.
Note: You can use a Feature circuit to change a 2-Speed pump to high speed.
Right button:
Assign the next circuit (
2
/4).
Up/Down buttons:
Select the first digit for the circuit number (
1
/4,
2
/4,
3
/4,
4
/4).
Right button:
Move to circuit setting.
Up/Down buttons:
Select the next circuit. When finished press the
Menu
button.
Solar:
Press the
Up/Down button
to select which solar screen to
view. Press the
Right
Press the
Up/Down button
to select which solar screen to view. Press the
Right button
to select the setting and the
Up/Down button
to change a
setting or value
.
Screen (1/3): ENABLE SOLAR:
Is the pool using solar heat? Select
Yes
or
No
to enable solar heat. To display the solar selection as a heat source in the
main screen, select
Yes
.
2-Speed Pmp 1/4
Circuit:
[SPA HEATER ]
Solar 1/3
Enable: Yes
Heat Pump: No
Solar 2/3
Enable Freeze
Enable: Yes/ No
Solar 3/3
Temperature Diff
Start: 6°
Run : 4°