![Pentair EASYTOUCH PL4 User Manual Download Page 28](http://html1.mh-extra.com/html/pentair/easytouch-pl4/easytouch-pl4_user-manual_1524370028.webp)
20
EASYTOUCH
®
PL4/PSL4 Control Systems User’s Guide
8. Configure the heater system options (page 30)
Set the type of heat source being used (Heater, Solar, Solar Preferred). Enable heat pump (UltraTemp
®
Heat
Pump) for heating/cooling if installed.
9. Configure the iS4 Spa-Side Remote (page 44)
Assign circuits to the iS4 Remote buttons. Once you have checked that all buttons operate properly, place
labels on remote buttons.
10. Set the delays feature (page 48)
Enable the one time “delay” feature for the heater, 2-speed pump, and automatic pool cleaner.
11. Schedule on/off times for circuit (page 32)
Set times for automatic circuit activation. Up to four (4) total programs can be created for all circuits
combined. One circuit can have up to a maximum of four (4) programs (4/4), or programs can be used by
separate circuits. All user created programs are active all the time; so check that there are not conflicting
automated times.
EasyTouch
®
PL4/PSL4 Control System Menus
MAIN SCREEN
LIGHTS
HEAT
POOL TEMP/SRC
TEMP (40° F - 104° F) OR (4° C - 41° C)
HEAT (OFF/HEATER/SOLAR/SOLAR PRF) - SOLAR/SOLAR PRF MUST BE ENABLED IN "SOLAR" MENU TO DISPLAY.
SPA TEMP/SRC
TEMP (40° F - 104° F) OR (4° C - 41° C)
HEAT (OFF/HEATER/SOLAR/SOLAR PRF) - "SOLAR/SOLAR PRF" MUST BE ENABLED IN "SOLAR" MENU TO DISPLAY.
DELAY CANCEL
MODE: SCHEDULE
08:00A -- 05:00P (12:00 AM - 11:59 PM -12 HOURS)
S M T W T F S (DAYS OF THE WEEK)
SCHEDULES
SPA
0
AUX 2 0
AUX 3 0
MODE: EGG TIMER
TIME: 12:00 (00:00 - 23:59) / DON'T STOP
SETTINGS
INTELLICHLOR
INTELLICHLOR 1/2 - ENABLE (YES/NO), POOL MODE: 0 - 100 % (50% default) SPA MODE: 0% (2% default)
INTELLICHLOR 2/2 - SUPER CHLR (ON/OFF), RUN HOURS (0 -72)
(OPTIONAL)
CIRCUIT NAMES
CIRCUIT NAMES (1/7) - [SPA, POOL, AUX1, AUX2, AUX3, FEATURE 1-2]
CIRCUIT FUNC.
CIRCUIT: (SPA [MASTER SPA], POOL [MASTER POOL], AUX 1-3, FEATURE 1-2, AUX EXTRA -
FREEZE: NO/YES
CUSTOM NAMES
CSTM NAME 1/7 (ASSIGN UP TO 100 CUSTOM NAMES)
[USERNAME-01...100] (UP TO 11 ALPHANUMERIC CHARACTERS)
2-SPEED PUMP
CIRCUIT (NONE, SPA, POOL, AUX1, AUX2,AUX3, FEATURE 1-2, SOLAR, HEATER, POOL HEATER, SPA HEATER, FREEZE)
2-SPEED PMP 1/4 (ASSIGN UP TO 4 CIRCUITS)
SOLAR
DELAYS
COOL DOWN (YES/NO) - VALVES (YES/NO)
SOLAR 1/2 - ENABLE (YES/NO) - HEAT PUMP (YES/NO) - SOLAR 2/3 - FREEZE,
SOLAR 3/3 (TEMPREATURE DIFFERENCE) - START (3
°
-9
°
(6° default)) - RUN (2
°
-5
°
(3° default))
VALVES
CLOCK
F
° /
C
°
iS4
FAHRENHEIT / CELCIUS
CIRCUIT - (NONE, SPA, POOL, AUX 1 - 3, FEATURE 1-2)
ASSIGN CIRCUITS 1/4
DATE & TIME 1/2 - (MONTH/DAY/YEAR) - (DAY/HOUR/MINUTES/AM/PM)
DATE & TIMER 2/2 - DAYLIGHT SAVING: (AUTO/MANUAL)
CLOCK ADJUST 00:00 (0 TO 300) - (-300 TO -5) IN 5 SCEOND INCREMENTS
(DELAYED CANCELLED) PRESS RIGHT BUTTON TO ACTIVATE
A: [NONE, SPA, POOL, AUX1, AUX2, AUX3, FEATURE 1-2, HEATER]
B: [NONE, SPA, POOL, AUX 1, AUX2, AUX3, FEATURE 1-2, HEATER]
POOL
0
AUX 1 0
MSTR CLEANER, LIGHT, SAM LIGHT, SAL LIGHT, PHOTON GENERATOR, COLOR WHEEL,
MODE: NEW / DELETE / NONE
HI-TEMP (SPA) / LO-TEMP (POOL) FOR SINGLE BODY SYSTEM (SEE SETTINGS MENU: CIRCUIT NAMES)
DIAGNOSTICS
SOFTWARE REV (REVISION LEVEL FOR THE OUTDOOR AND INDOOR CONTROL PANEL)
BOOTLOADER REV (REVISION LEVEL FOR THE OUTDOOR AND INDOOR CONTROL PANEL)
SELF TEST (STATUS: TESTING (FOLLOW ON-SCREEN PROMPTS TO TEST LCD AND BUTTONS) - CODE: 0 -
WATER TEMP (FAHRENHEIT/CELCIUS - STATUS DISPLAY ONLY)
SOLAR TEMP (FAHRENHEIT/CELCIUS - STATUS DISPLAY ONLY) - (DISPLAYS IF SOLAR IS ENABLED IN HEAT MENU)
AIR TEMP (FAHRENHEIT/CELCIUS - STATUS DISPLAY ONLY)
DISP OP CODES - DISPLAY? NO/YES (DISPLAYS TRANSMIT/RECEIVE PACKETS NUMBERS ON SCREEN)
SPA SIDE [OFF/ON]
ENABLE/DISABLE IS4 SPA-SIDE REMOTE
CIR NAMES [ON/OFF] VIEW DEFAULT CIRCUIT NAMES BEFORE MODIFICATION.
CHLORINATOR
SALT LEVEL: DISPLAYS CURRENT SALT LEVEL (XXXX) PPM
STATUS: OK - NO ERRORS (SUPER CHLORINATE, COM LINK ERROR, CHECK FLOW / PCB,
RESET SYSTEM (REINITIALIZE INDOOR CONTROL PANEL - USE RIGHT BUTTON)
FLASH UPDATE (USED FOR FIRMWARE UPDATES VIA PC - PRESS MENU TO ABORT)
INTELLIFLO
(OPTIONAL)
FEATURE 1-2 0
MODES [6 LIGHT SHOWS, HOLD, RECALL, COLOR SWIM, COLOR SET]
COLORS [5 FIXED COLORS, HOLD, RECALL, COLOR SWIM, COLOR SET]
ALL ON
(SWITCH ALL LIGHTS ON)
ALL OFF
(SWITCH ALL LIGHTS OFF)
SYNC
(SYNCHRONIZE COLORED LIGHTS)
MAGICSTREAM [TOGGLE THUMPER, HOLD, RESET, CHANGE MODE]
CONFIG (SETUP EIGHT LIGHT POSITIONS)
FEATURE CIR
FEATURE 1-2 [OFF]
FEATURE 1 - 2
MANUALLY TURN A FEATURE CIRCUIT ON/OFF.
USE FEATURE CIRCUITS TO CONTROL PUMP SPEEDS AND VALVES.
PUMP #1 - PUMP TYPE [VS, VSF, NONE]
HEAT PUMP COM
SETTINGS: ENABLE, DISABLE (NO/YES) - [HEATING, COOLING] - STATUS
(OPTIONAL)
QUICK TOUCH II
ASSIGN QT4 II 1/4 (ASSIGN UP TO 4 CIRCUITS)
CIRCUIT - (NONE, SPA, POOL, AUX 1 - 3, FEATURE 1-2)
ERASE EEPROM
ERASE ALL (YES /NO) - ARE YOU SURE? (YES/NO)
CALIBRATION
WATER (FAHRENHEIT/CELCIUS) - AIR (FAHRENHEIT/CELCIUS) - SOLAR (FAHRENHEIT/CELCIUS) -
SWITCH MANUAL HEAT ON OR OFF WHEN SPA IS MANUALLY SWITCHED ON (USE RIGHT BUTTON SELECT ON/OFF)
MAN HEAT [OFF/ON]
SET PASSWORD
SET PASSWORD: {XXXX} 4 DIGITS - ENABLE / DISABLE [NO/YES]
WIRELESS ADDR
SET AN ADDRESS FOR EASYTOUCH WIRELESS CONTROL PANEL
INTELLICHEM
PH/OPR Values (pH VAL, SET - OPR VAL, SET) - Status (pH/OPR level) - Saturation Index (CH,TDS,TA,SI)
(OPTIONAL)
WIRELESS ADDR
SET AN ADDRESS FOR EASYTOUCH WIRELESS CONTROL PANEL
BACKLIGHT
ON TIME: 5 S, 15 S, 30 S, 60 S, 5 M, OFF [BRIGHTNESS: LOW, MED HI]
POWER SAVE
IDLE TIME: 15 S, 30 S, 60 S, 5 ME
FILTERING, PRIMING, BACKWASH, VACUUM, STATUS
FUNCTIONS: GENERIC, MASTER SPA, MASTER POOL,
SPILLWAY, FLOOR CLEANER, INTELLIBRITE, MAGICSTREAM,
SOLAR MUST BE ENABLED IN "HEAT" MENU TO DISPLAY
SEE "TROUBLESHOOTING" SECTION FOR ERROR CODES)
LOW SALT, VERY LOW SALT, HIGH CURRENT, CLEAN CELL!!, LOW VOLTAGE)
WIRELESS CONTROL PANEL ONLY
Continue on next page.
A