![Pentair EASYTOUCH PL4 User Manual Download Page 21](http://html1.mh-extra.com/html/pentair/easytouch-pl4/easytouch-pl4_user-manual_1524370021.webp)
EASYTOUCH
®
PL4/PSL4 Control Systems User’s Guide
13
EasyTouch
®
PL4/PSL4 Control System Outdoor Control Panel Operating Modes
The EasyTouch PL4/PSL4 Control System can run in automatic mode or manual mode. Use the “Mode” button
to switch the system from “Auto” mode (normal operating mode) to “Service” for manual operation and service
purposes. Before operating the system, familiarize yourself with the LCD status messages and operating buttons.
AUTO (Automatic):
The system is in normal operating mode.
Scheduled programs will run automatically.
HEATER:
Displays the heat source (
Off, Heater, Solar Prf., Solar)
as specified in the Heater menu settings (see page 30). When the
Filter Pump (F) button is pressed in “Pool” or “Spa” mode, and heat
source is enabled (Heater button LED on).
POOL (SPA):
Indicates that the Valves (V) button is in “Pool” or
“Spa” mode and the Filter Pump (F) button has been pressed to
switch on the filter pump. If this display line is blank, it indicates no
spa or pool function is active. For a single body system, Hi-Temp
(Spa) / Lo-Temp (Pool) sets the temperature settings (see page 44)
85° F / 100° F:
Displays the actual spa or pool water temperature
(85° F) and the set point temperature (100° F) as set in the “Heat”
menu (see page 30).
AIR:
Displays the actual outside air temperature (70° F) as read by
the air sensor located near the Power Center.
Date and Time:
Displays the system day and time as specified in
the “Clock” menu settings (see page 34).
Valves (V) button:
When in normal
operating mode, the system is in “Pool”
mode so that only the pool water is
circulated through the system. Press the
Valves button to enable “Spa” mode and to
rotate valves and activate the Filter pump
(Filter Pump LED on) automatically so that
only the spa water is circulated through the
system. Note that the filter pump will switch
off while the pool/spa valves are rotating
into position.
“Fill/Spillway” and “Drain”
modes are used only in “Service” mode.
MENU / BACK button:
Access the system menu.
Also used to save and exit
from a current menu or
sub-menu settings. While
in menu mode, all system
control panel buttons are
disabled. Press this button
twice to refresh the display.
AUTO HEATER
SPA 85°F / 100°F
AIR 70°F
MON 09:30 AM
Filter Pump button:
For spa operations, press the
Valves (V)
button to rotate
valves into “Spa” mode, then
press the
Filter (F)
button
to activate the filter pump.
Press the Valves button to
toggle to “Pool” mode. The
Heater button LED will be on
if a heat source is enabled in
the Heat menu.
Left and Right
Button:
Use these buttons to
lower and raise the
current set point water
temperature level.