![Pentair EASYTOUCH PL4 User Manual Download Page 15](http://html1.mh-extra.com/html/pentair/easytouch-pl4/easytouch-pl4_user-manual_1524370015.webp)
EASYTOUCH
®
PL4/PSL4 Control Systems User’s Guide
7
AUTO HEATER
SPA 85°F / 100°F
AIR 70°F FRZ
MON 09:30 AM
EasyTouch
®
PL4/PSL4 Control System Indoor Control Panel (Optional)
The EasyTouch PL4/PSL4 Control System Indoor Control Panel allows you to control the pool and spa daily
operations from around your pool area or inside your home. Use the “P” (Pool) and “Spa” (Pool) buttons to
heat and filter your pool and spa. The indoor control panel connects to the EasyTouch PL4/PSL4 Control
System main circuit board located in the Power Center.
EasyTouch PL4/PSL4 Control System Indoor Control Panel
Spa (Hi-Temp) Button
:
Switches the filter pump
on, rotates valve actuator
(to isolate spa water from
pool water), and switches
the heater on. Hi-Temp
(single body system) sets
the high temperature
settings for the spa.
Pool (Lo-Temp) Button
:
Switches the filter pump
on, rotates valve
actuator (to isolate pool
water from spa water),
and switches heater on.
Lo-Temp (single body
system) sets the low
temperature
settings for the pool.
Set Temperature buttons,
see page 3.
Circuit LED.
Circuit name
label.
Three (3) user defined
auxiliary circuits. But-
tons switch the as-
signed circuit function
on/off.
(Default time is a 12
hour time-out).
(Left arrow button)
Lower set temperature
(Right arrow button)
Raise set temperatur
e
AUTO (Automatic):
The system is in normal operating mode.
Scheduled programs will run automatically. SERVICE or TIMEOUT mode are displayed when
the system is being serviced. These modes are activated from the Outdoor Control Panel.
HEATER:
Heater is switched on. Displays when the Pool (P) or Spa button is pressed. For
pool operations the heat source must be enabled in the Heat menu (see page 30). Displays
“Solar” or “Solar Prf” if solar is enabled. The heater is active when the set temperature is
higher than the water temperature. The heater will switch off when the water temperature rises
above the set temperature.
SPA (Hi-T) or POOL (LO-T) :
Displays when the Spa/HI-T or Pool/LO-T button is pressed to
rotate valve actuators and activate the filter pump and heater. This line on the screen is blank
when no spa or pool function is active. Note: Depending on the configuration of the PL4/PLS4
Control System, the screen displays SPA (shared equipment - EasyTouch PSL4 Control
System), HI-T (single body of water - EasyTouch PL4 Control System).
system), POOL (shared equipment), LO-T (single body of water system).
85° F / 100° F:
Displays the actual spa or pool water temperature
(85° F) and the set point temperature (100° F) as set in the Heater menu. Degree units are
displayed in either Fahrenheit or Celsius.
AIR:
Displays the actual outside air temperature (70° F) as read by the air sensor located near
the PL4/PLS4 Control System Power Center. Degree units are displayed in either Fahrenheit
or Celsius (see page 49).
FRZ:
Displays when freeze protection is active. To protect pool system equipment, freeze
protection must be enabled for the filter pump circuit. If the outside air temperature sensor
detects the temperature is getting close to freezing point (below 36° F (2° C)), the freeze
protection feature switches on the filter pump circuit to circulate water through the system. For
more information, see page 44.
DEL:
Displays when “Delay Cancel” is active. For more information, see page 31.
Date and Time:
Displays the PL4/PLS4 Control System day and time as specified in the
“Clock” menu setting (see page 34).