Summary of Contents for EASYTOUCH PL4

Page 1: ...FOR POOL AND SPA EASYTOUCH PL4 PSL4 CONTROL SYSTEM IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS USER S GUIDE ...

Page 2: ...P N 522461 Rev C 2 2020 Customer Service Technical Support USA Phone 800 831 7133 8 A M to 7 30 P M ET Fax 805 284 4151 Web sites visit www pentairpool com and staritepool com ...

Page 3: ...emperature settings 14 Schedule start and stop times for equipment 14 Schedules 14 Heat your spa or pool 15 Controlling Lights 16 Switch on lights manually and synchronize light colors 16 Schedule start and stop times for equipment 16 Setting the Egg Time Feature One time schedule 18 Section 2 Setting up the EasyTouch PL4 PSL4 Control Systems 19 EasyTouch PL4 PSL4 Menus 20 Main Screen 22 Feature C...

Page 4: ...nu Set Password 52 Settings Menu Wireless Addr 53 Settings Menu Backlight Wireless Controller 53 Settings Menu Power Save Wireless Controller 54 Spa Side Off On 54 Diagnostics Menu Software Rev 55 Diagnostics Menu Bootloader Rev 55 Diagnostics Menu Self Test 55 Diagnostics Menu Chlorinator 56 Diagnostics Menu Water Temp 56 Diagnostics Menu Solar Temp 56 Diagnostics Menu Air Temp 57 Diagnostics Men...

Page 5: ...LOWEST SPEED with a high speed override capability being for a temporary period not to exceed one normal cycle or two hours whichever is less To reduce the risk of injury do not permit children to use this product unless they are closely supervised at all times Control System is intended to control heaters with built in high limit circuits only Failure to do so may cause property damage or persona...

Page 6: ...ion and two No 6 AWG for Canadian installations solid copper conductor between this unit and any metal equipment metal enclosures or electrical equipment metal water pipe or conduit within 5 feet 1 5 m of the unit 5 The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with in accordance with the National E...

Page 7: ...erate using an antenna of a type and maximum or lesser gain approved for the transmitter by Industry Canada To reduce potential radio interference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication This device complies with Industry Canada licence exempt RSS standard ...

Page 8: ...are included in the EasyTouch PL4 PSL4 Control System kit The optional IntelliChlor Salt Chlorine Generator with separate Power Supply may also include the kit EasyTouch PL4 PSL4 Control Panel mounted in the Power Center EasyTouch PL4 PSL4 Power Center enclosure Two motorized valve actuators CVA 24T P N 263045 PSL4 EasyTouch Control System Shared body of water only Water sensor with 25 foot cable ...

Page 9: ...l Enable Disable Solar Heating Option Support Heat Pump Support RS485 Support Heat Pump Cooling Support Safety and Functional Delay s and Cancel Systems Delays Real Time Clock Assignable Circuit Names and Custom Circuit Names Special Circuit Types Function Two Speed Pump Support English Metric Support Sensor Calibration Password Protection EasyTouch PL4 PSL4 Control Systems Overview Welcome to the...

Page 10: ...2 is environmentally friendly and produces no secondary pollution into the treated water by salts such as chlorides or sulfates IntelliChem also supports IntelliChlor Salt Chlorine Generator to help manage your pool water sanitizer levels Indoor Control Panel optional The EasyTouch PL4 PSL4 Indoor Control Panel provides you with one touch automatic control for all of your pool and spa daily operat...

Page 11: ...rcuits P N 522465 Optional Low Voltage DC circuit breakers EasyTouch PL4 PSL4 Control System Outdoor Control Panel not shown Connects to Outdoor Control Panel RS 485 COM port located on EasyTouch PL4 PSL4 Control System Power Center main circuit board Wireless Controller 3 AUX circuits P N 522464 Optional IntelliChlor Salt Chlorine Generator with separate Power Center IC20 P N 520554 520556 IC40 P...

Page 12: ...SL4 outdoor control panel can be password protected To access a password protected control panel simply enter the assigned the four digit password see page 52 EasyTouch PL4 PSL4 Control System Outdoor Control Panel Controls Liquid Crystal Display LCD The main system display consists of a 16 x 4 alphanumeric character LCD with EL backlighting for easy viewing of the menu items and status messages P...

Page 13: ...er pump will automatically switch off after 10 minutes to allow the heater to cool down Pentair Water Pool and Spa heaters do not require a cool down time To override the heater cool down press the Filter Pump button again to switch off the pump Two Speed Filter Pump Press the Filter Pump button LED on to switch the two speed pump on in high speed If you switch the pump off to low speed shortly af...

Page 14: ...it relay is switched on manually it remains on until either you switch it off manually or the next time the relay is scheduled to be switched off For example if the filter pump is scheduled to automatically run from 9 00 AM to 5 00 PM daily then the filter pump is switched on manually at 9 00 PM schedule interrupted it will run continuously until the next day at 6 00 PM then switch off The schedul...

Page 15: ...utton is pressed For pool operations the heat source must be enabled in the Heat menu see page 30 Displays Solar or Solar Prf if solar is enabled The heater is active when the set temperature is higher than the water temperature The heater will switch off when the water temperature rises above the set temperature SPA Hi T or POOL LO T Displays when the Spa HI T or Pool LO T button is pressed to ro...

Page 16: ...ater This line on the screen is blank when no spa or pool function is active Note Depending on the configuration of the PL4 PLS4 Control System the screen displays SPA shared equipment EasyTouch PSL4 Control System HI T single body of water system EasyTouch PL4 Control System POOL shared equipment LO T single body of water system 85 F 100 F Displays the actual spa or pool water temperature 85 F an...

Page 17: ...ontrol panel Filter Pump F button Valves V button and Heater button if enabled in the Heat menu will be on If this display line is blank it indicates no pool or spa function is currently active Notes about Freeze Protection This function protects the pool plumbing and equipment against freeze damage If the outside air temperature sensor falls below 36 F 2 C Freeze Protection is activated and the F...

Page 18: ...nuously until the next day at 5 00 PM then switch off The schedule will then continue from then on AUX buttons are disabled while in the main menu Note A circuit turned on manually will run as long as the Egg Timer is set for default 12 hours Power ON Menu Back button Wireless Controller Use this button to power on the EasyTouch PL4 PSL4 Wireless Controller If there has been no button activity for...

Page 19: ...ttery icon is located in the lower right corner of the main screen EasyTouch PL4 PLS4 Control System Wireless Controller Power Saving Options and Changing Batteries AUTO HEATER SPA 85 F 100 F AIR 70 F MON 09 30 AM Power Save Options Use the power save function to reduce power consumption and extend battery life The power save options are Idle Time If there is no control panel activity the idle tim...

Page 20: ...ure that the battery cover is secure and that all the screws are hand tightened CAUTION DO NOT OVER TIGHTEN THE SCREWS OVER TIGHTENING THE SCREWS CAN DAMAGE THE UNIT 4 Power up the unit To switch the unit on press the Power On button located on the front of the unit 5 Display messages after replacing batteries After replacing depleted batteries a check battery message is displayed on the screen Pr...

Page 21: ...set in the Heat menu see page 30 AIR Displays the actual outside air temperature 70 F as read by the air sensor located near the Power Center Date and Time Displays the system day and time as specified in the Clock menu settings see page 34 Valves V button When in normal operating mode the system is in Pool mode so that only the pool water is circulated through the system Press the Valves button t...

Page 22: ... and backyard lights For example the filter pump relay circuit can be scheduled to run the daily pool and spa filtration at a specific time and day s of the week Up to 4 total program schedules may be created for all relay circuits combined The pool and spa circuits can also be scheduled to switch on the heater to heat the pool or spa water up to the set point temperature as set in the Heat menu s...

Page 23: ...will heat to the settings specified The EasyTouch PL4 PSL4 Control System allows for solar and conventional heaters The system will use the heating source that is selected The heat source selections are OFF No heating even though pump and other circuits may be operating HEATER Gas heater only SOLAR Solar heating system to be the only heat source In order to display Solar Only as a heat option in t...

Page 24: ...synchronize light colors From the Lights screen you can manually switch all lights on or off and synchronize colored lights Up to three 3 lights can be controlled For more information about setting up lights including IntelliBrite LED lights and MagicStream laminars refer to Lights Menu on page 25 MENU sLIGHTS sALL ON To manually switch on all lights and synchronize light colors Press the Up Down ...

Page 25: ...m If there are existing programs assigned to this circuit use these buttons to view and select the existing program settings Right button To select the Schedule settings Right button Move to start and stop time settings Up Down and Right buttons Set start and stop hour A P minutes The A AM and P PM time is set when setting the start and stop hour Right button Move to days of the week to run the pr...

Page 26: ...sSCHEDULESwSPA POOL Right button Select the Spa or Pool circuit You can also select any of the available circuits The generic circuit names are Spa Pool Aux 1 3 and Feature 1 2 Right button Select Mode if there are existing programs Skip this step to create a new program Up Down button Select New to create a new program Right button To create a new program and enter the Mode settings Up Down butto...

Page 27: ...e of the available circuit functions For the complete list of preset Circuit Functions If an auxiliary circuit AUX is assigned GENERIC simple ON OFF when the button is pushed then nothing needs to be done 5 Create Feature Circuits to conserve relays page 23 If you need to conserve physical auxiliary Power Center relays there are two 2 Feature Circuits available that you can assign to circuit funct...

Page 28: ...CUIT NAMES 1 7 SPA POOL AUX1 AUX2 AUX3 FEATURE 1 2 CIRCUIT FUNC CIRCUIT SPA MASTER SPA POOL MASTER POOL AUX 1 3 FEATURE 1 2 AUX EXTRA FREEZE NO YES CUSTOM NAMES CSTM NAME 1 7 ASSIGN UP TO 100 CUSTOM NAMES USERNAME 01 100 UP TO 11 ALPHANUMERIC CHARACTERS 2 SPEED PUMP CIRCUIT NONE SPA POOL AUX1 AUX2 AUX3 FEATURE 1 2 SOLAR HEATER POOL HEATER SPA HEATER FREEZE 2 SPEED PMP 1 4 ASSIGN UP TO 4 CIRCUITS S...

Page 29: ...D BUTTONS CODE 0 WATER TEMP FAHRENHEIT CELCIUS STATUS DISPLAY ONLY SOLAR TEMP FAHRENHEIT CELCIUS STATUS DISPLAY ONLY DISPLAYS IF SOLAR IS ENABLED IN HEAT MENU AIR TEMP FAHRENHEIT CELCIUS STATUS DISPLAY ONLY DISP OP CODES DISPLAY NO YES DISPLAYS TRANSMIT RECEIVE PACKETS NUMBERS ON SCREEN SPA SIDE OFF ON ENABLE DISABLE IS4 SPA SIDE REMOTE CIR NAMES ON OFF VIEW DEFAULT CIRCUIT NAMES BEFORE MODIFICATI...

Page 30: ...only SOLAR ONLY Solar heating system to be the only heat source In order to display Solar Pref on the main screen you must first enable solar in the Solar menu see page 30 SOLAR PREF Solar Preferred For when solar and gas heating are combined and you want to use solar heating only when it is most effective In order to display Solar Pref on the main screen you must first enable solar in the Solar m...

Page 31: ...r wheel For more information about setting up lights see Settings Menu Circuit Function on page 44 MENUsLIGHTSwLIGHTS The Color Swim and Color Set Lighting Features Modes Colors All On All Off Hold Recall Color Swim Color Set The Color Swim and Color Set lighting features is selected from the LIGHTS MODES and COLORS menu At least two 2 IntelliBrite SAm SAL and or FIBERworks lighting systems are re...

Page 32: ...to the Settings menu Press the Down button to and select Circuit Func Press the Right button to access the Circuit Func menu Up Down buttons Select the already assigned circuit name Pool Light Right button View Circuit Functions to assign to light circuit Pool Light Up Down buttons Select the type of light circuit function to use The circuit function names are LIGHT SAM LIGHT SAL LIGHT PHOTON GEN ...

Page 33: ... Slow color transitions creating a mesmerizing and calming effect Caribbean Transitions between a variety of blues and greens American Patriotic red white and blue transition Sunset Dramatic transitions of orange red and magenta tones Royalty Richer deeper color tones IntelliBrite Light If the IntelliBrite light was not previously on after selecting a color show mode no illumination will occur for...

Page 34: ...s Choose a color for the light Right button Switch the selected colored light ON To switch the light off go to themainLightsmenuandselectAllOff orpresstheAUXbuttonassignedtothe light The AUX button will also switch the light on Press the Menu button three times to return main menu Hold Recall Select Hold and Recall from the Modes or Color screen to capture and save a unique color effect and recall...

Page 35: ... SAm and or SAL and or FIBERworks have been assigned in Circuit Functions as SAM or SAL light If FIBERworks lighting is incorporated it also has to be set up as a PHOTON GENERATOR light for the circuit controlling the light bulb and COLOR WHEEL for the circuit controlling the color wheel it self The circuit light functions are Light SAM SAL Photon Generator Color Wheel and IntelliBrite lights see ...

Page 36: ... the MagicStream laminar circuit On Off button The generic circuits names are Spa Pool Aux 1 3 FEATURE 1 2 Ft 1 2 The circuit number 1 7 corresponds to its assigned circuit name Right button Select one of the system preset circuit names and or user defined custom circuit names Up Down buttons Scroll through the list of preset names see page 38 for a complete list of circuit names Select a name tha...

Page 37: ...is mode multiple laminars will synchronize colors together Note To sync multiple laminars two or more AUX circuits be sure to define the MagicStream circuits in the Circuit Functions menu Random Colors will change at ten 10 second intervals in a random sequence In this mode multiple laminars will NOT synchronize colors together Party Colors will change randomly and slowly at first then speed up un...

Page 38: ... enable solar in the Solar menu see page 47 SOLAR PREF Solar Preferred Solar and gas heating systems are installed and you want to use solar heating only when it is most effective In order to display Solar Pref on the main screen you must first enable solar in the Solar menu To set the spa temperature and select the heat source Pool Temp Src To set the pool temperature and select the heat source M...

Page 39: ...for 5 minutes Some heaters require a cool down cycle before being switched off This can be setup in the menu to run the filter pump an additional ten minutes to dissipate residual heat built up inside the heater combustion chamber The Delay Cancel feature is mainly for use by service technicians when it s necessary to shut the filter pump off immediately and know the heater has not been running He...

Page 40: ...New to create a new program Use None when a circuit has existing programs and you wish to exit the Mode selections without modifying the existing programs Choose the type Mode of program to run After selecting New the current program number 1 1 for this circuit is displayed Right button To move to the Mode selections Up Down button Choose the program to run Schedule Egg Timer New Delete and None I...

Page 41: ...a circuit to switch the filter pump on and rotate the valves into the Spa position and switch the heater on for one time only This example can also be used if you wanted to program when to filter and heat your pool and switch light or auxiliary circuits on To set the Egg Timer feature MENUsSCHEDULESwSPA Press the Up Down button to select the circuit to schedule then press the Right button Right bu...

Page 42: ...tons Adjust the offset in five second increments Press the Menu button to save the settings and to return to the Settings menu options Press the button again to return to the main menu options or press again to return to the main screen Settings Menu IntelliFlo IntelliFlo and IntelliPro pump The EasyTouch PL4 PSL4 Control System communicates with the IntelliFlo pump via a two wire RS 485 cable PN ...

Page 43: ...ol System indoor wireless or outdoor control panel first set the address on the pump itself The pump s default address is pump 1 To assign an IntelliFlo VS 3050 pump address 1 Be sure that the pump is powered on and the green power LED is on 2 Press the Stop buttons to stop the pump 3 Press and hold both the Start and Stop buttons until the red LED will starts flashing then press one of the four s...

Page 44: ...s 30 GPM The preset speed for each button is Speed 1 button 1100 RPM 30 GPM Speed 2 button 1500 RPM Speed 3 button 2350 RPM and Speed 4 button 3110 RPM Right button GPM PSI Move to PSI pounds per square inch pressure setting Up Down button Select the pump pressure setting from 1 to 30 PSI See above for equivalent default RPM GPM speed flow rate VS and VSF SVRS CIRCUIT SETTING Right button Move to ...

Page 45: ...er button to save the changes To cancel any changes press the Escape button to exit edit mode without saving NOTE INTELLIFLO FREEZE PROTECTION If the IntelliFlo pump is on due to a freeze condition not switch on from a relay circuit state and if a freeze speed flow is set this setting takes priority even if the previous setting is lower than the default circuit speed If no freeze protection is set...

Page 46: ...tons Set the chlorination output level for the spa water from 0 to 20 Right button Move to the next set of settings 2 2 Up Down buttons Select 2 2 Right button Move the Super Chlorination settings Up Down buttons Set Super Chlorination On or Off See note below about Super Chlorination Right button Move to Run Hours setting Up Down buttons Set the number of hours to run Super Chlorination 24 hours ...

Page 47: ... pH reducer and chlorine or bromine for the correct sanitization and pH balance IntelliChem controller operates with or without a salt chlorine generator to provide a self replenishing supply of chlorine generated from salt For more information refer to the IntelliChem Controller Installation and User s Guide P N 521363 From the IntelliChem controller menu you can adjust the pH and Oxidation Reduc...

Page 48: ...y Calcium hardness is the calcium carbonate scale deposited on pool surfaces The test for Calcium Hardness is a measure of how hard or soft the water is testing Hard water can have high levels of calcium and magnesium If these levels are too high the water becomes saturated and will leave calcium carbonate scale deposits a white ish crystallized rough spot on any surface inside the pool If the lev...

Page 49: ...e UltraTemp Heat Pump temperature and cooling Heat Pump Com To access Heat Pump Com UltraTemp Heat Pump settings menu MENUsSETTINGSsHEAT PUMP COMwSETTINGS Right button Access the Settings menu Up Down buttons Select Yes or No to enable or disable UltraTemp Right button Move to the Heating setting Up Down buttons Select Yes or No to use for heating Right button Move to the Cooling setting Up Down b...

Page 50: ... generic circuits names are Spa 1 7 Pool 2 7 Aux 1 3 3 5 7 Ft 1 2 6 7 7 The circuit number 1 7 corresponds to its assigned circuit name This name can be changed to suit the function Right button Move to system preset circuit names and user defined custom circuit names Up Down buttons Scroll through the list of alphabetical programmed names If you cannot find a name to match your circuit you can cr...

Page 51: ...__ USERNAME 02 ____________________ USERNAME 03 ____________________ USERNAME 04 ____________________ USERNAME 05 ____________________ USERNAME 06 ____________________ USERNAME 07 ____________________ USERNAME 08 ____________________ USERNAME 09 ____________________ USERNAME 10 ____________________ MALIBU LTS MIST MUSIC NOT USED OZONATOR PATH LIGHTS PATIO LTS PERIMETER L PG2000 POND LIGHT POOL PUM...

Page 52: ...ction MENUsSETTINGSsCIRCUIT FUNC wCIRCUIT FUNC Up Down buttons Choose the circuit name displayed on the second line The generic circuits names are SPA MASTER SPA Freeze protection on by default POOL MASTER POOL Freeze protection on by default AUX 1 3 FEATURE 1 2 Right button Move to the Circuit Function setting to select the circuit function for the select circuit name displayed on the line above ...

Page 53: ...r ALL lights off SAM Light Activates special color lighting programs on other screens on the Indoor Control Panel when used with SAM pool lights For example you can have ALL lights on or ALL lights off SAL Light Activates special color lighting programs on other screens on the Indoor Control Panel when used with SAL spa lights For example you can have ALL lights on or ALL lights off Photon Generat...

Page 54: ...er features By assigning AUX circuits to control valve actuators you can conserve auxiliary circuits for high voltage relays for controlling pumps and lights Valve A Resides on the EasyTouch PL4 PSL4 Control System main circuit board If solar heating is setup and is not configured as a heat pump then Valve A is dedicated for controlling the solar heating valve actuator Solar is enabled in the Sola...

Page 55: ...Control System main circuit board If a solar booster pump is being installed connect the pump to a power relay and plug a low voltage cable from relay into the two pin socket marked SOLAR on the EasyTouch PL4 PSL4 Control System main circuit board To access the Solar menu MENUsSETTINGwSOLARwSOLAR Up Down buttons Select a circuit that will switch the filter pump to high speed You can set up to four...

Page 56: ...3 Solar temperature differential start up and run settings Start Set the temperature differential to start heating from 3 to 9 For example if Start is set to 3 this ensures that the temperature has to deviate by 3 at least to the specified set point temperature in the Heat menu on page 25 before it switches on Once the solar comes on it will start converging as it is heating This ensures that it w...

Page 57: ...ing the iS4 Spa Side remote controller assign names to the circuits see page 45 To assign iS4 Spa Side buttons MENUsSETTINGsIS4wASSIGN IS4 Up Down buttons Select a circuit to one of the iS4 buttons You can set up to four circuits 1 4 2 4 3 4 4 4 Right button Move to the circuit setting Up Down buttons To configure the first button on the iS4 Spa Side Remote scroll through the circuit names and fin...

Page 58: ...C button activates Auxiliary 3 circuit Assign QT4 II Remote To assign circuits to the QuickTouch II Wireless Controller buttons MENUsSETTINGsQUICKTOUCHwASSIGN QT4 Up Down buttons Select a circuit to assign to one of the QuickTouch wireless remote buttons You can set up to four circuits 1 4 2 4 3 4 4 4 Right button Move to the circuit setting Up Down buttons To configure the first button 1 4 on the...

Page 59: ...body of water since the temperature sensor is common to both the pool and spa The system must be in Service mode to calibrate sensors Calibration Before you start you need an accurate all weather thermometer If you are calibrating the air sensor wait until the sensor is not in direct sunlight For the air temperature sensor make sure that the sensor is located in the shade for accurate readings To ...

Page 60: ... stored and retained in Flash memory in an EEPROM located on the control panel main circuit board and optional Indoor Control Panel The EasyTouch PL4 PSL4 Control System user system configuration data can be erased to restore the factory defaults settings System information automatically downloads from programmed components to non programmed components in case of accidental memory loss and to ease...

Page 61: ...ontrol System Wireless Controller a unique communication address to allow the wireless device to operate with the EasyTouch PL4 PSL4 Control System outdoor control panel see page 64 Wireless Addr To search and lock on to the EasyTouch PL4 PSL4 Control System wireless controller MENUsSETTINGsWIRELESS ADDRwPress Right Arrow button Address Wireless Sending Address MENU Address Wireless Scanning BACKL...

Page 62: ...isable the iS4 Spa Side remote This feature is useful for families with young children or when you go on vacation It allows you to switch off the iS4 Spa Side remote at the control panel so that the remote cannot be used Spa Side To enable or disable the iS4 Spa Side remote MENUsSPA SIDE ON OFF Right button Select On or Off to enable or disable the spa side remote Press the Menu button to save the...

Page 63: ...nal Indoor Control Panel is connected to the system Power Center Status Passed Code 0 After you have completed the test an error code is displayed Passed is displayed if the test was successful For error code descriptions see Self Test Error Codes on page 59 Press the Menu button to return to the Settings menu options Press the button again to return to the main menu options or press again to retu...

Page 64: ...The IntelliChlor will continue to produce chlorine at a reduced level VERY LOW SALT Not enough salt in pool The water salt level has fallen below 2500 parts per million ppm IntelliChlor will not produce chlorine until additional salt is added manually HIGH CURRENT Check IntelliChlor electrolytic cell controller Refer to IntelliChlor User s Guide troubleshooting information CLEAN CELL Cell has calc...

Page 65: ... in order to update the firmware MENUsDIAGNOSTICSsFLASH UPDATE Press the Menu button to exit the flash mode Diagnostics Menu Air Temp Displays the current outside air temperature MENUsDIAGNOSTICSsAIR TEMP Press the Menu button to return to the Settings menu options Press the button again to return to the main menu options or press again to return to the main screen Diagnostics Menu Cir Name Off On...

Page 66: ...58 EASYTOUCH PL4 PSL4 Control Systems User s Guide EasyTouch PL4 PSL4 Control System Wiring Diagram Outdoor Control Panel ...

Page 67: ...r heating Go to the Heat menu see page 30 and enable Solar as the heat source MENUsHEATsSOLAR Note Do not set solar as a heat pump Then the heating method must be selected for each body of water EasyTouch PL4 PSL4 Control System Error Messages Error Messages If the system detects that a sensor is not connected to the EasyTouch PL4 PSL4 Control System Power Center or it is defective an error messag...

Page 68: ... For example Code 3 would indicate a problem with the LEDs on the control panel If multiple errors are detected multiple code numbers are displayed For example Codes 4 2 1 would indicate problems detected with the buttons LEDs and the LCD backlight on the control panel The following lists the control panel self test error codes Error Code Table EasyTouch PL4 PSL4 Control System Error Messages Cont...

Page 69: ... salt is added manually See IntelliChlor SC User s Guide for details HIGH CURRENT Check IntelliChlor SC electrolytic cell Check IntelliChlor electrolytic cell controller Refer to IntelliChlor SC User s Guide troubleshooting information CLEAN CELL Cell has calcium build up and requires cleaning Cell has calcium build up and requires cleaning Refer to IntelliChlor SC User s Guide for cleaning instru...

Page 70: ...osis Use the following information to resolve control system problems Problem The control system works in Service Mode but EasyTouch PL4 PSL4 Control System Indoor Control Panel fails to operate Symptom Possible Cause Solution Indoor Control Panel has no power screen blank no LEDs buttons not working Bad wiring run from Outdoor Control Panel main circuit board in the Power Center Verify cable and ...

Page 71: ... the Power Center Verify the function of the board using known good cable set Defective receiver board Replace receiver board Address switches are incor rectly configured Verify that the address switches on the transmitter and handheld receiver board are correct and match Transmitter battery has failed Replace Transmitter battery Defective Transmitter or Receiver Unit functions but some circuits d...

Page 72: ...d when equipment is running Undue electrical noise is being produced by one or more pieces of equipment in close proximity to the receiver Relocate the Receiver away from equipment such as blower motors Relocate the receiver in a location that provides fewer obstructions to the area the user com monly operates the transmitter Unit operates but has greatly reduced range compared to prior function T...

Page 73: ...rned to the pool A spa bypass line divert a small amount of water to the spa Make sure the filter pump turns on correctly If the pump has two speeds Press the button one time to run the pump in low speed Press the button again to run the pump in high speed Press the button again to switch the pump off A Two Speed pump has to be configured in the 2 Speed menu see page 46 6 Set both valve actuators ...

Page 74: ...ry message is displayed on the screen Press the MENU button twice to continue 4 Press Menu button and select Settings Address and press the Right arrow button 5 Select Address and press the Right arrow button to lock on to the unique address that is being transmitted from the outdoor control panel Note If you choose Abort the device can continue to operate using the factory default address If the ...

Page 75: ...ge from the indoor or wireless control panel to the EasyTouch PL4 PSL4 Control System outdoor control panel Note To erase existing control panel system information use the Erase EEPROM feature Refer to Erase EEPROM on page 52 for more information Wiring UltraTemp Heat Pump to EasyTouch PL4 PSL4 Control System Be sure to check the UltraTemp Heat Pump terminal block wire colors and pinouts located o...

Page 76: ...nel Control panel with flexible hinge installed in upper portion of Power Center to control EasyTouch PL4 PSL4 control system Power Center Metal enclosure with power relays transformer and 18 V and 24 V internal circuit breakers Used for distributing power for controlling EasyTouch PL4 PSL4 control system Low Voltage Compartment Top compartment of Power Center for all low voltage wiring Low Voltag...

Page 77: ...EASYTOUCH PL4 PSL4 Control Systems User s Guide 69 NOTES ...

Page 78: ...70 EASYTOUCH PL4 PSL4 Control Systems User s Guide NOTES ...

Page 79: ...EASYTOUCH PL4 PSL4 Control Systems User s Guide 71 NOTES ...

Page 80: ... Pentair trademarks and logos are property of Pentair Inc or its global affiliates in the U S A and or other countries Third party registered and unregistered trademarks and logos are the property of their respective owners 2020 Pentair All rights reserved This document is subject to change without notice 522461 P N 522461 REV C 2 2020 ...

Reviews: