1
installation
140
Electrical connection
For the connection, use an approved cable, in accordance with the regulations.
The cable must bear one of the following indications: H05V2V2-F, H05RR-F or
H05RN-F.
There is a label on the underside of the appliance with the wiring diagrams.
The connection terminals are accessible once you have opened the junction
box on the underneath. The junction box cover can be opened with a
screwdriver.
If you want to make a fixed connection, make sure that a multi-polar switch with
a contact separation of at least 3 mm is fitted in the supply line.
Power setting table
Type of hob
Component voltage
230V/50Hz
Appliance width x depth
774 x 512 mm
Installation height from
top of worktop
56 mm
Cut out dimensions width x depth
750 x 490 mm
Capacities of modules
Left
3000
130
2800
W
warming
Right
W
W
Induction
zone
700001871100_IDK835_4t.qxd 12-10-2005 12:47 Pagina 140