Possibilities for building in
Ventilation
The electronics in the appliance
require cooling. The ventilation
openings are located on the underside
of the appliance. It must be possible
for cool air to be drawn in through
these openings. The appliance is fitted
with outlet openings at the front.
The kitchen unit will require a few modifications to allow optimum cooling of
the hob.
Above drawer or fixed panel
Saw out the ventilation openings
(min. 100 cm
2
). Ventilation is via plinth
and rear of cupboard.
Do not allow the ventilation openings
on the underside of the appliance to
be blocked by a drawer.
Where there is a drawer, a gap of at
least 560 x 6 mm should be made at
the front. The distance between drawer
A and the hob should be a minimum of
10 mm. No extra modifications for
ventilation need be made where there
is a fixed panel.
150
A
min.
560 x 6 mm
min.
10 mm