Value
Function
Description
7
Fault reset (RESET)
The terminal is used for fault reset function, the same
as the function of RESET key on the operation panel.
Remote fault reset is implemented by this function.
8
Normally open (NO)
input of external fault
If this terminal becomes ON, the AC drive reports
E00d and performs the fault protection action.For
more details, see the description of F05.21.
9
Terminal UP
If the frequency is determined by external terminals,
the terminals with the two functions are used as
increment and decrement commands for frequency
modification.
10
Terminal DOWN
11
Clear UP/ DOWN
(
terminal
、
keypad
)
12
Multi-speed terminal 1
The setting of 16 speed or 16 other commands can
be implemented through combinations of 16 states of
these four terminals.
13
Multi-speed terminal 2
14
Multi-speed terminal 3
15
Multi-speed terminal 4
16
Pause operation
The AC drive decelerates to stop, but the running
parameters are all memorized, such as PLC, swing
frequency and PID parameters. After this function is
disabled, the AC drive resumes its status before
stop.
17
Acc/ Dec time
selection 1
Totally four groups of acceleration/deceleration time
can be selected through combinations of two states
of these two terminals.
18
Acc/ Dec time
selection 2
19
Frequency source
switchover
The terminal is used to perform switchover between
two frequency sources according to the setting in
F00.09.
20
Run command
switchover terminal
If the command source is set to terminal control
(F00.01= 1), this terminal is used to perform
switchover between terminal control and keypad
control. If the command source is set to
communication control (F00.01 = 2), this terminal is
used to perform switchover between communication
control and keypad control.