Function
code
Name
Description
(setting range)
Factory
Default
Change
F06.07
S8 terminal
function
selection
15: multi-speed terminal 4
16: Pause operation
17: Acc/Dec time selection 1
18: Acc/ Dec time selection 2
19: frequency source switch over
20: run command switch over terminal
21: Acceleration/Deceleration prohibited
22: PID pause
23: PLC status reset
24: swing pause
25: terminal count
26: counter reset
27: length count input
28: length reset
29: torque control prohibited
30: pulse input (enabled only for HDI)
31: reserved
32: immediate DC braking
33: Normally closed (NC) input of
external fault
34: frequency modification forbidden
35: reverse PID action direction
36: external STOP terminal 1
37: command source switch over
terminal 2
38: PID integral pause
39: reserved
40: reserved
41: motor selection terminal 1
42: reserved
43: PID parameter switch over
44: reserved
45: reserved
46: speed/torque control switchover
47: emergency stop
0
●
F06.08
S9 terminal
function
selection
0
●
F06.09
HDI terminal
function
selection
0
●
-61-
Chapter 5 Function & Parameter Table
C
h
a
p
te
r
5
Peaco Support FC280 Series VFD User Manual