-63-
Chapter 5 Function & Parameter Table
Function
code
Name
Description
(setting range)
Factory
Default
Change
F06.21
Corresponding setting
of AI1 upper limit
-100.0%
~+
100.0%
100.0%
※
F06.22
AI1 input filter time
0.00s
~
10.00s
0.10s
※
F06.23
AI2 low limit
0.00V
~
F06.25
0.00V
※
F06.24
Corresponding setting
of AI2 lower limit
-
100.0%
~+
100.0%
0.0%
※
F06.25
Ai2 upper limit
F06.23
~+
10.00V
10.00V
※
F06.26
Corresponding setting
of AI2 upper limit
-
100.0%
~+
100.0%
100.0%
※
F06.27
Ai2 input filter time
0.00s
~
10.00s
0.10s
※
F06.28
Ai3 lower limit
-10.00V
~
F06.30
0.10V
※
F06.29
Corresponding setting
of AI3 lower limit
-100.0%
~+
100.0%
0
※
F06.30
Ai3 upper limit
F06.28
~+
10.00V
4.00V
※
F06.31
Corresponding setting
of AI3 upper limit
-100.0%
~+
100.0%
100.0%
※
F06.32
Ai3 input filter time
0.00s
~
10.00s
0.10s
※
F06.33
HDI lower limit
0.00kHz
~
F06.35
0.00kHz
※
F06.34
Corresponding setting
of HDI lower limit
-100.0%
~+
100.0%
0.0%
※
F06.35
HDI upper limit
F06.33
~+
100.00kHz
50.00kHz
※
F06.36
Corresponding setting
of HDI upper limit
-100.0%
~+
100.0%
100.0%
※
F06.37
HDI frequency input
filter time
0.00s
~
10.00s
0.10s
※
F06.38
AI curve selection
units'digit: AI curve selection
1: curve 1( 2 point, see
F06.18
~
F06.21)
2: curve 2( 2 point, see
F06.23
~
F06.26)
3: curve 3( 2 point, see
F06.28
~
F06.31)
H.321
※
C
h
a
p
te
r
5