Function
code
Name
Description
(setting range)
Factory
Default
Change
F11.07
Number of pulses per
meter
0.1
~
6553.5
100.0
※
F11.08
Set count value
1
~
65535
1000
※
F11.09
Designated count value
1
~
65535
1000
※
Group F12: Simple PLC Function And Multi-speed control
F12.00
Simple PLC running
mode
0: Stop after the AC drive
runs one cycle
1: Keep final values after
the AC drive
runs one cycle
2: Repeat after the AC
drive runs one cycle
0
※
F12.01
Simple PLC retentive
selection
Unit's digit: Retentive upon
power failure
0: No
1: Yes
Ten's digit: Retentive upon
stop
0: No
1: Yes
00
※
F12.02
Multi-speed 0
-100.0%
~
100.0%
0.0%
※
F12.03
Multi-speed 1
-100.0%
~
100.0%
0.0%
※
F12.04
Multi-speed 2
-100.0%
~
100.0%
0.0%
※
F12.05
Multi-speed 3
-100.0%
~
100.0%
0.0%
※
F12.06
Multi-speed 4
-100.0%
~
100.0%
0.0%
※
F12.07
Multi-speed 5
-100.0%
~
100.0%
0.0%
※
F12.08
Multi-speed 6
-100.0%
~
100.0%
0.0%
※
F12.09
Multi-speed 7
-100.0%
~
100.0%
0.0%
※
F12.10
Multi-speed 8
-100.0%
~
100.0%
0.0%
※
F12.11
Multi-speed 9
-100.0%
~
100.0%
0.0%
※
F12.12
Multi-speed 10
-100.0%
~
100.0%
0.0%
※
F12.13
Multi-speed 11
-100.0%
~
100.0%
0.0%
※
-77-
Chapter 5 Function & Parameter Table
C
h
a
p
te
r
5
Peaco Support FC280 Series VFD User Manual