Function
code
Name
Description
(setting range)
Factory
Default
Change
F05.21
Fault
protection
action
selection 1
Unit's digit:motor overload
(
E007
)
0:coast to stop
1:stop according to the stop mode
2:continue to run
Ten's digit :power input phase loss (E012)
Hundred's digit:power output phase loss
(E013)
Thousand's digit:external equipment
fault(E00d)
Ten thousand's digit:communication
fault(E018)
00000
※
F05.22
Fault
protection
action
selection 2
Unit's digit:encoder/PG card fault(E026)
0:coast to stop
Ten's digit:EEPROM read-write
fault(E021)
0:coast to stop
1:stop according to the stop mode
Hundred's digit: reserved
Thousand's digit: motor overheat(E036)
Ten thousand's digit
(Accumulative running time
reached)(E020)
00000
※
F05.23
Fault
protection
action
selection 3
Unit's digit: reserved Ten's digit: reserved
Hundred's digit (Accumulative power-on
time reached( E029)
0: coast to stop
1: stop according to the stop mode
2: continue to run
Thousand's digit: off load( E030)
0: coast to stop
1: decelerate to stop
2: continue to run at 7% of rated motor
frequency and resume to the set
frequency if the load recovers
00000
※