Chapter 5 Function & Parameter Table
Function
code
Name
Description
(setting range)
Factory
Default
Change
F02.36
Encoder wire-break
fault detection time
0.0s: No action
0.1–10.0s
0.0
●
F02.37
Self-learning of motor
parameter
0: no self-learning
1: dynamic self- learning of
asynchronous motor
2: static self- learning of
asynchronous motor
0
●
Group F03: Vector Control Parameters
F03.00
Proportional gain 1 of
speed loop
1
~
100
30
※
F03.01
Integral time 1 of speed
loop
0.01s
~
10.00s
0.50s
※
F03.02
Switchover low point
frequency
0.00Hz
~
F03.05
5.00Hz
※
F03.03
Proportional gain 2 of
speed loop
1
~
100
20
※
F03.04
Integral time 2 of speed
loop
0.01s
~
10.00s
1.00s
※
F03.05
Switchover high point
frequency
F03.02
~
F00.03( max.
frequency)
10.00Hz
※
F03.06
Vector control slip gain
50%
~
200%
100%
※
F03.07
Speed loop output filter 0.000s
~
0.100s
0.000s
※
F03.08
Vector control over
excitation gain
0
~
200
64
※
F03.09
Torque upper limit
source in speed control
mode
0:F03.10
1:analog AI1
2:analog AI2
3:analog AI3
4:Pulse
(
HDI
)
5:RS485 Communication
6:MIN(AI1,AI2)
7:MAX(AI1,AI2)
(corresponding to F03.10
digital setting)
0
※
C
h
a
p
te
r
5
Peaco Support FC280 Series VFD User Manual