![Patton electronics SmartWare R.3.20 Software Configuration Manual Download Page 467](http://html1.mh-extra.com/html/patton-electronics/smartware-r-3-20/smartware-r-3-20_software-configuration-manual_4044387467.webp)
ISDN port configuration task list
467
SmartWare Software Configuration Guide
35 • ISDN port configuration
Layer 3
Protocol: Dss1
UniSide: Net
MinChannel: 0
MaxChannel: 1
MaxCalls: 2
AIS Blue Alarm: off
Hunt Mode: Ascending
Signalling Mode: Etsi
Examples
Example:
Configuring BRI port as Euro-ISDN interface
The following example shows how to configure port 0/0 as a Euro ISDN interface with user side signaling.
172.16.40.71(cfg)#port bri 0 0
172.16.40.71(prt-bri)[0/0]#q921
172.16.40.71(q921)[0/0]#q931
172.16.40.71(q931)[0/0]#uni-side user
172.16.40.71(q931)[0/0]#encapsulation cc-isdn
172.16.40.71(q931)[0/0]#bind interface bri00
172.16.40.71(q931)[0/0]#exit
172.16.40.71(q921)[0/0]#exit
172.16.40.71(prt-bri)[0/0]#no shutdown
Example: being clock slave on uni network interface
The following example shows how to configure both ports of a SmartNode 1400 with network signaling but
receive the clock (via port 0) from the peer. The peer must be configured accordingly, i.e. port 0 as USR/clock
master and port 1 NET/clock slave.
172.16.40.71(cfg)#port bri 0 0
172.16.40.71(prt-bri)[0/0]#clock slave
172.16.40.71(prt-bri)[0/0]#q921
172.16.40.71(q921)[0/0]#q931
172.16.40.71(q931)[0/0]#uni-side net
172.16.40.71(q931)[0/0]#encapsulation cc-isdn
172.16.40.71(q931)[0/0]#bind interface bri00
172.16.40.71(q931)[0/0]#exit
172.16.40.71(q921)[0/0]#exit
172.16.40.71(prt-bri)[0/0]#no shutdown
172.16.40.71(cfg)#port bri 0 1
172.16.40.71(prt-bri)[0/0]#q921
172.16.40.71(q921)[0/0]#q931
172.16.40.71(q931)[0/0]#uni-side net
172.16.40.71(q931)[0/0]#encapsulation cc-isdn
172.16.40.71(q931)[0/0]#bind interface bri01
172.16.40.71(q931)[0/0]#exit
172.16.40.71(q921)[0/0]#exit
172.16.40.71(prt-bri)[0/0]#no shutdown