REGULATORY COMPLIANCE UL AND CE
IPA Hardware Installation Guide
95
You must install a mains power line filter on both the Motor power mains and Control power mains if they are to
be used independently. Use the following tables to determine the correct filter for your specific application.
Control Power
Control power is 1 Ampere, maximum. Any of the following filters works with all models of the IPA drive.
Control Power Filter Selection
Filter
Manufacturer
FN670-3/06
Schaffner
6EP1 (160937-5)
Corcom
10EP1 (160937-7)
1,
Corcom
FN2070-10/06
Schaffner
1. Available from Parker: 10 Amp filter—part number 47-016140-01
Mains Motor Power
Mains Motor Power Filter Selection
Filter
Continuous Current (Amps) IPA04-HC
IPA15-HC
6EP1 (160937-5)
1
5 at 240 VAC
10EP1 (160937-7)
1, 3
8 at 240 VAC
x
x
FN2070-10/06
2
10 at 240 VAC
x
x
FN2070-12/06
12 at 240 VAC
x
x
FN2070-16/06
2, 3
16 at 240 VAC
x
x
Product with applicable mains filter denoted by “x”
1. Corcom (a division of Tyco Electronics)
2. Schaffner
3. Available from Parker: 10 Amp filter—part number 47-016140-01
Install transient suppressors
.
You must install varistors or other voltage surge limiting devices in order to meet
the requirements of IEC 61000-4-5. Place a Littelfuse V275LA2ØC, or an equivalent varistor, from line to line and
from lines to earth before the mains filter, as shown in the
EMC Installation
drawings. (Intersil, General Electric, and
Littelfuse manufacture equivalent varistors.)
Use an EMC-ready motor or a motor that has demonstrated acceptable EMC performance
. Motors
with shielded cabling or pipe thread style cabling options allow the easiest integration into machines required to
bear the CE mark for EMC.
Note: Motors may bear the CE mark. This mark indicates the motor meets the requirements of
construction and safety—
not EMC compliance
.
Summary of Contents for IPA Series
Page 2: ......
Page 14: ...INTRODUCTION 14 IPA Hardware Installation Guide CHAPTER 1 Introduction...
Page 18: ...MECHANICAL INSTALLATION 18 IPA Hardware Installation Guide CHAPTER 2 Mechanical Installation...
Page 24: ...ELECTRICAL INSTALLATION 24 IPA Hardware Installation Guide CHAPTER 3 Electrical Installation...
Page 54: ...TROUBLESHOOTING 54 IPA Hardware Installation Guide CHAPTER 4 Communications...
Page 63: ...TROUBLESHOOTING IPA Hardware Installation Guide 63 CHAPTER 5 Troubleshooting...
Page 77: ......
Page 100: ...REGULATORY COMPLIANCE UL AND CE 100 IPA Hardware Installation Guide...
Page 101: ......
Page 102: ...APPENDIX A 102 IPA Hardware Installation Guide APPENDIX A VM25 Expansion Module...
Page 114: ...APPENDIX C 114 IPA Hardware Installation Guide APPENDIX C IPA with Parker Mechanics...