If THALL reports a 1, 2, or 4, change SHALL from either 0 to 1 or from 1 to 0. After you change SHALL,
reset the drive/controller.
3
Repeat step 1 until THALL reports a value of 6.
4
The wire on the negative voltage or ground is motor wire W. The two wires at the positive voltage are U
and V.
Now there are two possibilities:
a.
Connect the motor wires to the terminals. Operate the drive in DMODE1. If the motor does
not turn in the clockwise direction, exchange motor wires U and V. Verify that the Bit 8455
command is set to zero (Ø).
b.
Put positive voltage on motor wire W together with either U or V and put negative voltage or
ground on the remaining wire. If THALL reports a value of 3, the wire at the negative voltage is
V. If THALL reports a value of 5, the wire at the negative voltage is U.
Figure 33. -
Hall Connection Diagram
Procedure 2
—
Hall Wires
Use this procedure to connect your Hall wires to the IPA.
1
First operate the IPA in DMODE1 and verify that the motor turns clockwise. If not, swap any two motor
wires.
2
Remove the motor input power leads, leaving the feedback cable connected to the drive/controller.
Connect motor input power wires U and V and slowly apply a positive voltage with respect to W. (See
Figure 33).
Note: A variable low voltage (5-24V) current limiting power supply (less than continuous current
rating of motor) is preferred.
Summary of Contents for IPA Series
Page 2: ......
Page 14: ...INTRODUCTION 14 IPA Hardware Installation Guide CHAPTER 1 Introduction...
Page 18: ...MECHANICAL INSTALLATION 18 IPA Hardware Installation Guide CHAPTER 2 Mechanical Installation...
Page 24: ...ELECTRICAL INSTALLATION 24 IPA Hardware Installation Guide CHAPTER 3 Electrical Installation...
Page 54: ...TROUBLESHOOTING 54 IPA Hardware Installation Guide CHAPTER 4 Communications...
Page 63: ...TROUBLESHOOTING IPA Hardware Installation Guide 63 CHAPTER 5 Troubleshooting...
Page 77: ......
Page 100: ...REGULATORY COMPLIANCE UL AND CE 100 IPA Hardware Installation Guide...
Page 101: ......
Page 102: ...APPENDIX A 102 IPA Hardware Installation Guide APPENDIX A VM25 Expansion Module...
Page 114: ...APPENDIX C 114 IPA Hardware Installation Guide APPENDIX C IPA with Parker Mechanics...