Internal Regeneration Capability
The drive/controller may experience an over-voltage fault if the regeneration exceeds the absorbent capacity of
the drive/controller’s internal bus capacitors, as shown in the following table.
The available absorption varies, based on mains voltage and the drive/controller’s internal capacitance. The various
drives can absorb the following amounts of regenerated energy in its internal capacitors.
Regeneration Absorption
Model
Absorbs
(Joules)
120 VAC
Absorbs
(Joules) 240
VAC
IPA04
110
37
IPA15
184
62