ADDITIONAL SPECIFICATIONS
86
IPA Hardware Installation Guide
Resetting the fault
To clear the latched fault, choose one of the following methods:
Cycle power to the drive/controller.
–or–
Open ACR-View and issue the DRIVE RES AXIS0 command to the IPA.
Drive/Controller Over-Temperature Protection
The IPA over-temperature circuit monitors the drive/controller’s internal temperature. If the sensors exceed the
threshold temperature, the unit issues an over-temperature fault.
Threshold Temperature
Description
Specification
All models
80°C (176°F) minimum
Results of Fault
Power to motor is turned off
Drive status word is updated via Ethernet to the PC
(See the table “LED Drive Over-Temperature Fault”)
LED Drive Over-Temperature Fault
LED Middle
LED Top
Yellow &
3 Green (blinking)
Red
Resetting the fault
After the internal temperature has dropped below the values shown in the “Reset Temperature Values” table, you
can clear the latched fault. There are two methods available:
Cycle power to the drive/controller.
–or–
Open ACR-View and issue the DRIVE RES AXIS0 command to the IPA.
Reset Temperature Values
Description
Specification
All models
75°C (167°F)
Summary of Contents for IPA Series
Page 2: ......
Page 14: ...INTRODUCTION 14 IPA Hardware Installation Guide CHAPTER 1 Introduction...
Page 18: ...MECHANICAL INSTALLATION 18 IPA Hardware Installation Guide CHAPTER 2 Mechanical Installation...
Page 24: ...ELECTRICAL INSTALLATION 24 IPA Hardware Installation Guide CHAPTER 3 Electrical Installation...
Page 54: ...TROUBLESHOOTING 54 IPA Hardware Installation Guide CHAPTER 4 Communications...
Page 63: ...TROUBLESHOOTING IPA Hardware Installation Guide 63 CHAPTER 5 Troubleshooting...
Page 77: ......
Page 100: ...REGULATORY COMPLIANCE UL AND CE 100 IPA Hardware Installation Guide...
Page 101: ......
Page 102: ...APPENDIX A 102 IPA Hardware Installation Guide APPENDIX A VM25 Expansion Module...
Page 114: ...APPENDIX C 114 IPA Hardware Installation Guide APPENDIX C IPA with Parker Mechanics...