ELECTRICAL INSTALLATION
42
IPA Hardware Installation Guide
Output (Motor) Power
Output Power Ratings
Continuous and peak output power ratings for all IPA models are listed in the following table.
Output Power Ratings
Model
Continuous Peak Max
Cont. Max Peak
Current (RMS) Current (RMS) Shaft Power (Watts) Shaft Power (Watts)
IPA04-HC
3.00
9.00
400
1200
IPA15-HC
6.30
18.90
1500
4500
Output (Motor) Power Connections
The following figure shows how to connect the motor cable to the Output Power connector.
Figure 13. -
Output Power Connection
Current Parker motor cables are marked with white numbers (1, 2, or 3) to indicate the phase. Connect Motor
Phase 1 to U, 2 to V, and 3 to W, and Motor Safety Earth to the Protective Earth ground connector.
Warning:
You must connect the Motor Safety Earth conductor terminal,
marked with the earth symbol , to the motor cable’s motor-
safety-earth wire green/yellow).
The following table contains wiring information for making connections with various Parker Hannifin motors.
Wiring to Parker Motors
Phase
Hi-Flex/ PS/Gemini
Legacy Parker Hannifin
U
1
Red/Yellow
V
2
White/Yellow
W
3
Black/Yellow
Green/Yellow
Green/Yellow
Summary of Contents for IPA Series
Page 2: ......
Page 14: ...INTRODUCTION 14 IPA Hardware Installation Guide CHAPTER 1 Introduction...
Page 18: ...MECHANICAL INSTALLATION 18 IPA Hardware Installation Guide CHAPTER 2 Mechanical Installation...
Page 24: ...ELECTRICAL INSTALLATION 24 IPA Hardware Installation Guide CHAPTER 3 Electrical Installation...
Page 54: ...TROUBLESHOOTING 54 IPA Hardware Installation Guide CHAPTER 4 Communications...
Page 63: ...TROUBLESHOOTING IPA Hardware Installation Guide 63 CHAPTER 5 Troubleshooting...
Page 77: ......
Page 100: ...REGULATORY COMPLIANCE UL AND CE 100 IPA Hardware Installation Guide...
Page 101: ......
Page 102: ...APPENDIX A 102 IPA Hardware Installation Guide APPENDIX A VM25 Expansion Module...
Page 114: ...APPENDIX C 114 IPA Hardware Installation Guide APPENDIX C IPA with Parker Mechanics...